Differential Uptake and Release of Female Genital Secretions Components and HPV DNA by Veil, Swab, and Vaginal Tampon

<b>Background/Objectives</b>: Self-collection devices are more widely used than ever for detecting sexually transmitted infections and cervical cancer. Despite this, we still lack a clear understanding of how well these tools actually collect and release the necessary molecular samples. This study compared the in vitro uptake and release performance of commonly used self-sampling devices for total proteins, nucleic acids, and episomal human papillomavirus type 16 (HPV-16) DNA. <b>Methods:</b> An artificial cervicovaginal fluid composed of phosphate-buffered saline supplemented with serum and nucleic acid extracts was serially diluted 2-fold. Each dilution was applied for 5 min to the external surfaces of a vaginal veil (Vaginal Veil Collector V-Veil UP2<sup>TM</sup> device), a flocked swab (FLOQSwabs<sup>®</sup>), and a commercial vaginal tampon. Non-woven surgical tissue and plastic film served as controls. Total proteins and nucleic acids were quantified by spectrophotometry, and HPV-16 DNA by real-time quantitative PCR. <b>Results:</b> Recovery rates for proteins and nucleic acids were highest for the vaginal veil (81% and 91%), followed by the swab (66% and 70%) and non-woven tissue (44% and 47%). In contrast, the tampon and plastic film performed poorly, releasing less than 30% of proteins and negligible amounts of nucleic acids. Episomal HPV-16 DNA release was highest for the veil (89%), compared with the swab (57%), non-woven tissue (37%), tampon (4%), and plastic film (2%). <b>Conclusions:</b> The vaginal veil demonstrated superior uptake and release of proteins, nucleic acids, and HPV-16 DNA at physiological concentrations. Its non-absorbent structure allows high saturation with efficient release of genital components, including microbial genomes, whereas vaginal tampons retained these components, limiting analytical recovery.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-01-23
DOI
https://doi.org/10.3390/diagnostics16030380
Primary Topic
Cervical Cancer and HPV Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Differential Uptake and Release of Female Genital Secretions Components and HPV DNA by Veil, Swab, and Vaginal Tampon

L. Bélec, Ralph-Sydney Mboumba Bouassa, Jonathan Muwonga Tukisadila
Diagnostics
Cervical Cancer and HPV Research
article

Differential Uptake and Release of Female Genital Secretions Components and HPV DNA by Veil, Swab, and Vaginal Tampon

L. Bélec, Ralph-Sydney Mboumba Bouassa, Jonathan Muwonga Tukisadila
article en

Abstract

<b>Background/Objectives</b>: Self-collection devices are more widely used than ever for detecting sexually transmitted infections and cervical cancer. Despite this, we still lack a clear understanding of how well these tools actually collect and release the necessary molecular samples. This study compared the in vitro uptake and release performance of commonly used self-sampling devices for total proteins, nucleic acids, and episomal human papillomavirus type 16 (HPV-16) DNA. <b>Methods:</b> An artificial cervicovaginal fluid composed of phosphate-buffered saline supplemented with serum and nucleic acid extracts was serially diluted 2-fold. Each dilution was applied for 5 min to the external surfaces of a vaginal veil (Vaginal Veil Collector V-Veil UP2<sup>TM</sup> device), a flocked swab (FLOQSwabs<sup>®</sup>), and a commercial vaginal tampon. Non-woven surgical tissue and plastic film served as controls. Total proteins and nucleic acids were quantified by spectrophotometry, and HPV-16 DNA by real-time quantitative PCR. <b>Results:</b> Recovery rates for proteins and nucleic acids were highest for the vaginal veil (81% and 91%), followed by the swab (66% and 70%) and non-woven tissue (44% and 47%). In contrast, the tampon and plastic film performed poorly, releasing less than 30% of proteins and negligible amounts of nucleic acids. Episomal HPV-16 DNA release was highest for the veil (89%), compared with the swab (57%), non-woven tissue (37%), tampon (4%), and plastic film (2%). <b>Conclusions:</b> The vaginal veil demonstrated superior uptake and release of proteins, nucleic acids, and HPV-16 DNA at physiological concentrations. Its non-absorbent structure allows high saturation with efficient release of genital components, including microbial genomes, whereas vaginal tampons retained these components, limiting analytical recovery.

DiagnosticsVol. 16(3)
Délégation Paris 5 (FR), University of Ottawa (CA), Université Paris Cité (FR), Montfort Hospital (CA), University of Kinshasa (CD), Assistance Publique – Hôpitaux de Paris (FR), Hôpital Européen Georges-Pompidou (FR), Hôpital Européen (FR), Centre International de Recherches Médicales de Franceville (GA), Institut du Savoir Montfort (CA)
Gender equality
Openalex Percentile: Top 80%
Cervical Cancer and HPV Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.