Quantification of the Real Contact Area of a Finger-Pad During Sliding Using a Novel Optical Coherence Tomography System and the Influence of Skin Thickness

Abstract Understanding the interaction of skin with surfaces is important as there are many applications where this is important, such as medicine (skin grafts), bioelectronics (sensors, robotic hands, and wearable technology), and consumer products, depending on the grip, dexterity, and feel of the objects. These phenomena are all strongly governed by frictional forces, which are intrinsically linked to the real area of contact. The real contact area, in turn, is modulated by factors such as skin hydration and the topographical roughness of the interacting surfaces. In this work, a new high-resolution optical coherence tomography (OCT) tool, developed in-house, was used to analyze the real contact area and the stratum corneum thickness in finger-pad interfaces due to its ability to penetrate and image the skin layers at high resolution. Data were compared with a lower-resolution VivoSight® OCT device used in previous work. Forty-seven finger-pad sliding tests against smooth glass were performed using three different volunteers with forces ranging from 0.5 to 3 N. Post-test analyses of the OCT images captured revealed that the real measured contact area was 54 ± 7% of the apparent contact area using the high-resolution OCT device in comparison to 63 ± 10% measured with the VivoSight OCT. This underscores the rationale for employing a high-resolution OCT system, as it enables precise visualization of the contact perimeter at the tribological interface, thereby facilitating a more accurate quantification of interfacial geometry and contact mechanics. The thickness of the stratum corneum was also seen to increase during sliding under the high-resolution OCT device. This resulted from the high skin deformation, which in turn influenced the contact area.

Authors

Institutions

Publication Details

Journal
Journal of Tribology
Published
2026-01-22
DOI
https://doi.org/10.1115/1.4070952
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of the Real Contact Area of a Finger-Pad During Sliding Using a Novel Optical Coherence Tomography System and the Influence of Skin Thickness

Matt Carré, Raman Maiti, Roger Lewis, Stephen J. Matcher et al.
Journal of Tribology
Optical Coherence Tomography Applications
article

Quantification of the Real Contact Area of a Finger-Pad During Sliding Using a Novel Optical Coherence Tomography System and the Influence of Skin Thickness

Matt Carré, Raman Maiti, Roger Lewis, Stephen J. Matcher, Wei Li, Zenghai Lu
article en

Abstract

Abstract Understanding the interaction of skin with surfaces is important as there are many applications where this is important, such as medicine (skin grafts), bioelectronics (sensors, robotic hands, and wearable technology), and consumer products, depending on the grip, dexterity, and feel of the objects. These phenomena are all strongly governed by frictional forces, which are intrinsically linked to the real area of contact. The real contact area, in turn, is modulated by factors such as skin hydration and the topographical roughness of the interacting surfaces. In this work, a new high-resolution optical coherence tomography (OCT) tool, developed in-house, was used to analyze the real contact area and the stratum corneum thickness in finger-pad interfaces due to its ability to penetrate and image the skin layers at high resolution. Data were compared with a lower-resolution VivoSight® OCT device used in previous work. Forty-seven finger-pad sliding tests against smooth glass were performed using three different volunteers with forces ranging from 0.5 to 3 N. Post-test analyses of the OCT images captured revealed that the real measured contact area was 54 ± 7% of the apparent contact area using the high-resolution OCT device in comparison to 63 ± 10% measured with the VivoSight OCT. This underscores the rationale for employing a high-resolution OCT system, as it enables precise visualization of the contact perimeter at the tribological interface, thereby facilitating a more accurate quantification of interfacial geometry and contact mechanics. The thickness of the stratum corneum was also seen to increase during sliding under the high-resolution OCT device. This resulted from the high skin deformation, which in turn influenced the contact area.

Journal of TribologyVol. 148(5)
Beijing Institute of Technology (CN), University of Huddersfield (GB), Loughborough University (GB), University of Sheffield (GB)
Sustainable cities and communities
Openalex Percentile: Top 80%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.