Test–retest reliability and responsiveness of the Self-Regulation Assessment in a rehabilitation population: A prospective multicentre validation study

ObjectiveThis study aimed to examine the test-retest reliability and responsiveness of the Self-Regulation Assessment, a recently developed patient-reported outcome measure designed to evaluate self-regulation in a multi-diagnostic rehabilitation population.DesignA prospective cohort study following COSMIN guidelines. Participants completed the Self-Regulation Assessment and other measurements at start of rehabilitation (T0), 6 months later (T1), and 2 weeks after T1 (T2). Test-retest reliability (T1-T2) was quantified by intraclass correlation coefficient values, Bland-Altman plots, and the smallest detectable change. Responsiveness (T0-T1) was quantified by hypothesis testing, effect size, area under the curve, and minimal important change based on the anchor Global Rating of Change scale of self-regulation.Setting and participantsInpatients and outpatients of 14 Dutch rehabilitation institutions with various diagnosis.Main measureThe Self-Regulation Assessment.ResultsIn total, 555 patients completed the Self-Regulation Assessment at T0 and T1 and 167 patients at T1 and T2. In inpatients and outpatients, the Self-Regulation Assessment showed adequate to good reliability, with smallest detectable changes ranging from 16.0 to 22.9 points at individual level and 1.5 to 3.3 at group level for outpatients and inpatients, respectively. Significant changes (T0-T1) were observed in both groups, with a small effect size for inpatients and large for outpatients. Hypothesis testing indicated near sufficient responsiveness in both groups (67% confirmed). Minimal important change values ranged from 6.25 to 9.8 points for outpatients.ConclusionThe Self-Regulation Assessment demonstrated sufficient reliability and detected changes at group level, but was not suitable for detecting changes at individual level in outpatient rehabilitation.

Authors

Institutions

Publication Details

Journal
Clinical Rehabilitation
Published
2026-01-23
DOI
https://doi.org/10.1177/02692155251413773
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test–retest reliability and responsiveness of the Self-Regulation Assessment in a rehabilitation population: A prospective multicentre validation study

Patrick Stegeman, Rob Smeets, J.A. de Graaf, M.M.R. Riemens et al.
Clinical Rehabilitation
Stroke Rehabilitation and Recovery
article

Test–retest reliability and responsiveness of the Self-Regulation Assessment in a rehabilitation population: A prospective multicentre validation study

Patrick Stegeman, Rob Smeets, J.A. de Graaf, M.M.R. Riemens, A.M. de Rooij, J. Stolwijk, M.W.M. Post, E.W.M. Scholten, J.M.A. Visser-Meily, S. Oberink, B.M.P. Mourits, P.E.C.A. Passier
article en

Abstract

ObjectiveThis study aimed to examine the test-retest reliability and responsiveness of the Self-Regulation Assessment, a recently developed patient-reported outcome measure designed to evaluate self-regulation in a multi-diagnostic rehabilitation population.DesignA prospective cohort study following COSMIN guidelines. Participants completed the Self-Regulation Assessment and other measurements at start of rehabilitation (T0), 6 months later (T1), and 2 weeks after T1 (T2). Test-retest reliability (T1-T2) was quantified by intraclass correlation coefficient values, Bland-Altman plots, and the smallest detectable change. Responsiveness (T0-T1) was quantified by hypothesis testing, effect size, area under the curve, and minimal important change based on the anchor Global Rating of Change scale of self-regulation.Setting and participantsInpatients and outpatients of 14 Dutch rehabilitation institutions with various diagnosis.Main measureThe Self-Regulation Assessment.ResultsIn total, 555 patients completed the Self-Regulation Assessment at T0 and T1 and 167 patients at T1 and T2. In inpatients and outpatients, the Self-Regulation Assessment showed adequate to good reliability, with smallest detectable changes ranging from 16.0 to 22.9 points at individual level and 1.5 to 3.3 at group level for outpatients and inpatients, respectively. Significant changes (T0-T1) were observed in both groups, with a small effect size for inpatients and large for outpatients. Hypothesis testing indicated near sufficient responsiveness in both groups (67% confirmed). Minimal important change values ranged from 6.25 to 9.8 points for outpatients.ConclusionThe Self-Regulation Assessment demonstrated sufficient reliability and detected changes at group level, but was not suitable for detecting changes at individual level in outpatient rehabilitation.

Clinical Rehabilitation
University of Groningen (NL), Gaustad Hospital (NO), University Medical Center Utrecht (NL), Maastricht University (NL), St. Antonius Ziekenhuis (NL), Revant (Netherlands) (NL), Nea International (Netherlands) (NL), Libra Revalidatie & Audiologie (NL), Heliomare (NL), De Hoogstraat Revalidatie (NL), Vrije Universiteit Amsterdam (NL)
Openalex Percentile: Top 81%
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.