Low-Load endoluminal navigation with a magnetically actuated medical soft microrobot

Minimally invasive endoluminal interventions increasingly rely on magnetic actuation to navigate narrow lumens while limiting wall loads. Here we present a contact-aware control framework for steering a deformable, silicone-based soft microrobot with embedded magnetic particles using an externally positioned permanent magnet. We develop a dynamic model capturing viscous drag, nonlinear frictional loads, and viscoelastic wall contact, and implement a closed-loop architecture that combines vision-based state estimation with model-based force inference while optimizing magnet orientation to regulate the force vector and normal reaction. Performance is evaluated in simulation and on a benchtop testbed across three control modes. In the nominal-case benchmark, force-plus-angle control reduced the root-mean-square tracking error from 4.8 to 2.1 mm (-56%), decreased peak tracking error from 14.6 to 8.0 mm (-45%), lowered the integrated performance index from 4.4 × 10<sup>-</sup>¹⁰ to 1.6 × 10<sup>-</sup>¹⁰ (-64%), and attenuated peak normal reaction force from 2.0 × 10<sup>-</sup> <sup>6</sup> to 0.8 × 10<sup>-</sup> <sup>6</sup> <i>N</i> (-60%) compared with operation without force regulation. To assess robustness, we further performed a simulation-based Monte Carlo analysis (<i>n</i> = 500 trials per mode) under parametric uncertainty and measurement noise, confirming that the contact-aware modes preserve their performance advantage; non-parametric tests indicated statistically significant inter-mode differences with moderate-to-large effect sizes. A trade-off analysis in the {tracking error, peak normal load} plane showed that, in the explored regime, improved tracking does not inherently require higher peak contact forces. Finally, a first-order shear-thinning surrogate suggested low sensitivity of the relative conclusions to moderate non-Newtonian effects. Overall, the results identify force-aware magnet orientation as a safety-relevant control degree of freedom for endoluminal navigation and provide a transferable control methodology for future magnetic microrobotic platforms.

Authors

Institutions

Publication Details

Journal
Frontiers in Medical Technology
Published
2026-01-23
DOI
https://doi.org/10.3389/fmedt.2026.1717944
Primary Topic
Micro and Nano Robotics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-Load endoluminal navigation with a magnetically actuated medical soft microrobot

Julio Guerra, Petr Ryapolov, Andres Santiago Martinez-Leon, Andrei Malchikov et al.
Frontiers in Medical Technology
Micro and Nano Robotics
article

Low-Load endoluminal navigation with a magnetically actuated medical soft microrobot

Julio Guerra, Petr Ryapolov, Andres Santiago Martinez-Leon, Andrei Malchikov, Sergey Jatsun
article en

Abstract

Minimally invasive endoluminal interventions increasingly rely on magnetic actuation to navigate narrow lumens while limiting wall loads. Here we present a contact-aware control framework for steering a deformable, silicone-based soft microrobot with embedded magnetic particles using an externally positioned permanent magnet. We develop a dynamic model capturing viscous drag, nonlinear frictional loads, and viscoelastic wall contact, and implement a closed-loop architecture that combines vision-based state estimation with model-based force inference while optimizing magnet orientation to regulate the force vector and normal reaction. Performance is evaluated in simulation and on a benchtop testbed across three control modes. In the nominal-case benchmark, force-plus-angle control reduced the root-mean-square tracking error from 4.8 to 2.1 mm (-56%), decreased peak tracking error from 14.6 to 8.0 mm (-45%), lowered the integrated performance index from 4.4 × 10<sup>-</sup>¹⁰ to 1.6 × 10<sup>-</sup>¹⁰ (-64%), and attenuated peak normal reaction force from 2.0 × 10<sup>-</sup> <sup>6</sup> to 0.8 × 10<sup>-</sup> <sup>6</sup> <i>N</i> (-60%) compared with operation without force regulation. To assess robustness, we further performed a simulation-based Monte Carlo analysis (<i>n</i> = 500 trials per mode) under parametric uncertainty and measurement noise, confirming that the contact-aware modes preserve their performance advantage; non-parametric tests indicated statistically significant inter-mode differences with moderate-to-large effect sizes. A trade-off analysis in the {tracking error, peak normal load} plane showed that, in the explored regime, improved tracking does not inherently require higher peak contact forces. Finally, a first-order shear-thinning surrogate suggested low sensitivity of the relative conclusions to moderate non-Newtonian effects. Overall, the results identify force-aware magnet orientation as a safety-relevant control degree of freedom for endoluminal navigation and provide a transferable control methodology for future magnetic microrobotic platforms.

Frontiers in Medical TechnologyVol. 8
Microelectronica (Romania) (RO), Universidad Estatal Amazónica (EC), Robotics Research (United States) (US), Universidad Técnica del Norte (EC)
Russian Science Foundation
Openalex Percentile: Top 77%
Micro and Nano Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.