Amplifying image quality gain in x-ray phase contrast imaging of mastectomy samples with deep learning denoising

<i>Objective.</i>Phase-contrast computed tomography (PCT) of the breast has previously been shown to produce higher-quality images at lower radiation doses without the need for breast compression. The present study is aimed at further reduction of the radiation dose in PCT, while preserving or further increasing the image quality, by applying supervised deep learning denoising of reconstructed PCT images. This work was carried out in preparation for live patient PCT breast cancer imaging, initially at specialised synchrotron facilities.<i>Approach.</i>PCT scans of 34 fresh full mastectomy samples were acquired using propagation-based phase-contrast imaging with 32 keV monochromatic parallel x-rays at mean glandular doses of 4 mGy and 24 mGy. All scans were reconstructed using Filtered Back Projection algorithm with Paganin's phase retrieval. A supervised U-Net-based deep learning denoising model was trained on 28 pairs of 4 mGy and 24 mGy scans and then applied to denoise the remaining 6 stacks of reconstructed 4 mGy images. Denoised PCT images were quantitatively evaluated using signal-to-noise ratio (SNR), spatial resolution, structural similarity index measure (SSIM) and peak-SNR (PSNR). The images were also visually compared and systematically assessed by experienced medical imaging specialists and radiologists.<i>Main results.</i>Deep learning denoising increased SNR by a factor of four while spatial resolution remained unchanged. SSIM and PSNR improved from 0.89 and 37 dB to 0.96 and 42 dB, respectively. Visual assessors significantly preferred the denoised images over the original 4 mGy images, and visual assessment indicated no increase in perceived artefacts in denoised images compared with the original 4 mGy images.<i>Significance.</i>Deep learning-based image denoising can further improve image quality in PCT without increasing radiation dose in imaging of mastectomies, supporting the feasibility of lower-dose PCT protocols or improved image quality for future clinical applications.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-01-22
DOI
https://doi.org/10.1088/1361-6560/ae3c54
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Amplifying image quality gain in x-ray phase contrast imaging of mastectomy samples with deep learning denoising

Ashkan Pakzad, Yakov I. Nesterets, C. R. Hall, Timur E. Gureyev et al.
Physics in Medicine and Biology
Advanced X-ray Imaging Techniques
article

Amplifying image quality gain in x-ray phase contrast imaging of mastectomy samples with deep learning denoising

Ashkan Pakzad, Yakov I. Nesterets, C. R. Hall, Timur E. Gureyev, Patrick Brennan, Thomas A. Leatham, Robert Turnbull, Beena Kumar, Daniel M. Häusermann, Anton Maksimenko, Simon J. Mutch, Amir Entezam, Seyedamir T Taba, Darren Lockie, Jane Fox, Benedicta D Arhatari, Harry Morris Quiney
article en

Abstract

<i>Objective.</i>Phase-contrast computed tomography (PCT) of the breast has previously been shown to produce higher-quality images at lower radiation doses without the need for breast compression. The present study is aimed at further reduction of the radiation dose in PCT, while preserving or further increasing the image quality, by applying supervised deep learning denoising of reconstructed PCT images. This work was carried out in preparation for live patient PCT breast cancer imaging, initially at specialised synchrotron facilities.<i>Approach.</i>PCT scans of 34 fresh full mastectomy samples were acquired using propagation-based phase-contrast imaging with 32 keV monochromatic parallel x-rays at mean glandular doses of 4 mGy and 24 mGy. All scans were reconstructed using Filtered Back Projection algorithm with Paganin's phase retrieval. A supervised U-Net-based deep learning denoising model was trained on 28 pairs of 4 mGy and 24 mGy scans and then applied to denoise the remaining 6 stacks of reconstructed 4 mGy images. Denoised PCT images were quantitatively evaluated using signal-to-noise ratio (SNR), spatial resolution, structural similarity index measure (SSIM) and peak-SNR (PSNR). The images were also visually compared and systematically assessed by experienced medical imaging specialists and radiologists.<i>Main results.</i>Deep learning denoising increased SNR by a factor of four while spatial resolution remained unchanged. SSIM and PSNR improved from 0.89 and 37 dB to 0.96 and 42 dB, respectively. Visual assessors significantly preferred the denoised images over the original 4 mGy images, and visual assessment indicated no increase in perceived artefacts in denoised images compared with the original 4 mGy images.<i>Significance.</i>Deep learning-based image denoising can further improve image quality in PCT without increasing radiation dose in imaging of mastectomies, supporting the feasibility of lower-dose PCT protocols or improved image quality for future clinical applications.

Physics in Medicine and BiologyVol. 71(3)
Commonwealth Scientific and Industrial Research Organisation (AU), The University of Sydney (AU), Australian Nuclear Science and Technology Organisation (AU), The University of Melbourne (AU), Australian Synchrotron (AU), Health Sciences and Nutrition (AU), Monash Health (AU), Breastscreen Victoria (AU), Monash University (AU)
Good health and well-being
Openalex Percentile: Top 80%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.