Clinical Image Quality and Reader Variability in 3D Synthetic Brain MRI Compared with Conventional MRI

<b>Background/Objectives</b>: This study evaluated the clinical image quality of three-dimensional synthetic MRI (3D SI) compared with conventional MRI (cMRI), focusing on tissue contrast, anatomical detail, and motion sensitivity. <b>Methods</b>: Patients with nonspecific neurological symptoms were included. Both cMRI and 3D SI were acquired on single-vendor 1.5 T and 3 T scanners with slice thicknesses of 1.0-1.7 mm. Two experienced neuroradiologists and one fellow independently evaluated matched scans using a 0-100 scale. Assessed parameters included signal-to-noise ratio (SNR), gray-white matter contrast, artifacts, motion robustness, and confidence in detecting perivascular spaces, white matter lesions, and subtle pathology. Interrater agreement was measured using Krippendorff's alpha and ICC2. Multiple linear regression analyzed associations between image quality ratings and imaging method. <b>Results</b>: Images of 31 patients were analyzed. Three-dimensional SI demonstrated sufficient-to-good overall image quality and high robustness to motion. Cortical-surface-to-cerebrospinal-fluid contrast on FLAIR was rated lower for 3D SI than for cMRI. False-positive lesion detection occurred more frequently on 3D SI FLAIR, particularly among experienced readers. cMRI achieved significantly higher T1-weighted SNR than 3D SI (8.76 points, <i>p</i> < 0.001). Experienced readers consistently rated SNR and tissue contrast higher than the fellow. Vascular signal range was broader on 3D SI, reducing sensitivity to vascular abnormalities. <b>Conclusions</b>: Three-dimensional synthetic MRI provides clinically usable image quality and fulfills its primary diagnostic purpose, offering advantages in acquisition efficiency and robustness to motion. Nevertheless, limitations in cortical contrast, vascular signal characterization, and reader-dependent interpretive variability constrain its reliability for subtle or detail-critical findings.

Authors

Institutions

Publication Details

Journal
Tomography
Published
2026-01-23
DOI
https://doi.org/10.3390/tomography12020013
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Image Quality and Reader Variability in 3D Synthetic Brain MRI Compared with Conventional MRI

Maria Blatow, Alexander von Hessling, Chloé Sieber, Dirk Lehnick et al.
Tomography
Advanced MRI Techniques and Applications
article

Clinical Image Quality and Reader Variability in 3D Synthetic Brain MRI Compared with Conventional MRI

Maria Blatow, Alexander von Hessling, Chloé Sieber, Dirk Lehnick, Christian Berner
article en

Abstract

<b>Background/Objectives</b>: This study evaluated the clinical image quality of three-dimensional synthetic MRI (3D SI) compared with conventional MRI (cMRI), focusing on tissue contrast, anatomical detail, and motion sensitivity. <b>Methods</b>: Patients with nonspecific neurological symptoms were included. Both cMRI and 3D SI were acquired on single-vendor 1.5 T and 3 T scanners with slice thicknesses of 1.0-1.7 mm. Two experienced neuroradiologists and one fellow independently evaluated matched scans using a 0-100 scale. Assessed parameters included signal-to-noise ratio (SNR), gray-white matter contrast, artifacts, motion robustness, and confidence in detecting perivascular spaces, white matter lesions, and subtle pathology. Interrater agreement was measured using Krippendorff's alpha and ICC2. Multiple linear regression analyzed associations between image quality ratings and imaging method. <b>Results</b>: Images of 31 patients were analyzed. Three-dimensional SI demonstrated sufficient-to-good overall image quality and high robustness to motion. Cortical-surface-to-cerebrospinal-fluid contrast on FLAIR was rated lower for 3D SI than for cMRI. False-positive lesion detection occurred more frequently on 3D SI FLAIR, particularly among experienced readers. cMRI achieved significantly higher T1-weighted SNR than 3D SI (8.76 points, <i>p</i> < 0.001). Experienced readers consistently rated SNR and tissue contrast higher than the fellow. Vascular signal range was broader on 3D SI, reducing sensitivity to vascular abnormalities. <b>Conclusions</b>: Three-dimensional synthetic MRI provides clinically usable image quality and fulfills its primary diagnostic purpose, offering advantages in acquisition efficiency and robustness to motion. Nevertheless, limitations in cortical contrast, vascular signal characterization, and reader-dependent interpretive variability constrain its reliability for subtle or detail-critical findings.

TomographyVol. 12(2)
University of Lucerne (CH)
Openalex Percentile: Top 81%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.