Correlation between lung ultrasound B lines and clinical as well as echocardiographic parameters in patients on maintenance hemodialysis

Patients with chronic kidney disease undergoing hemodialysis are at an increased risk of cardiovascular complications due to volume overload. Lung ultrasound (LUS) has emerged as a non-invasive tool to assess extravascular lung water (EVLW) and manage fluid excess. This study aimed to validate LUS in a relatively asymptomatic day-care dialysis population and to correlate it with clinical parameters, ECHO/IVC metrics. This prospective pre-post intervention study was conducted in a dialysis unit, enrolling 93 eligible hemodialysis patients. The fluid status of all patients was evaluated by clinical examination, lung ultrasound, inferior vena cava (IVC) indices, and echocardiography pre and post-dialysis. The mean age was 48.20 ± 13.81 years with male predominance (n = 66,71%). Only 28 patients (30%) had NYHA class III dyspnea. Edema and lung crackles were observed in 5 (5.4%) and 8 patients (8.6%), respectively. The Mean Lung USG B lines pre- and post -dialysis were 3.527 ± 4.636 and 0.484 ± 1.419, respectively. Pre-HD lung USG B-lines showed significant correlations with edema (p = 0.05) and echocardiographic parameters, such as E/E' ratio (r = 0.35, p = 0.001), E velocity (r = 0.21, p = 0.04), and pulmonary pressure (r = 0.33, p = 0.001). A moderately positive correlation was also found between the maximum diameter of the IVC pre-dialysis and lung USG B-lines (P < 0.001). Lung USG is a promising technique for estimating EVLW in patients on dialysis. Significant correlations between pre-dialysis lung USG B-lines and echocardiographic measures of cardiac function, IVC maximum diameter and edema suggest a link between cardiac performance and volume status. This could complement clinical skills in determining dry weight.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-23
DOI
https://doi.org/10.1038/s41598-025-32769-2
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation between lung ultrasound B lines and clinical as well as echocardiographic parameters in patients on maintenance hemodialysis

Jyoti Mannari, Jaishree Ganjiwale, Vivek Kute, Maulin Shah et al.
Scientific Reports
Ultrasound in Clinical Applications
article

Correlation between lung ultrasound B lines and clinical as well as echocardiographic parameters in patients on maintenance hemodialysis

Jyoti Mannari, Jaishree Ganjiwale, Vivek Kute, Maulin Shah, Rachit J. Patel, Reema D. Patel, Mitesh Makwana
article en

Abstract

Patients with chronic kidney disease undergoing hemodialysis are at an increased risk of cardiovascular complications due to volume overload. Lung ultrasound (LUS) has emerged as a non-invasive tool to assess extravascular lung water (EVLW) and manage fluid excess. This study aimed to validate LUS in a relatively asymptomatic day-care dialysis population and to correlate it with clinical parameters, ECHO/IVC metrics. This prospective pre-post intervention study was conducted in a dialysis unit, enrolling 93 eligible hemodialysis patients. The fluid status of all patients was evaluated by clinical examination, lung ultrasound, inferior vena cava (IVC) indices, and echocardiography pre and post-dialysis. The mean age was 48.20 ± 13.81 years with male predominance (n = 66,71%). Only 28 patients (30%) had NYHA class III dyspnea. Edema and lung crackles were observed in 5 (5.4%) and 8 patients (8.6%), respectively. The Mean Lung USG B lines pre- and post -dialysis were 3.527 ± 4.636 and 0.484 ± 1.419, respectively. Pre-HD lung USG B-lines showed significant correlations with edema (p = 0.05) and echocardiographic parameters, such as E/E' ratio (r = 0.35, p = 0.001), E velocity (r = 0.21, p = 0.04), and pulmonary pressure (r = 0.33, p = 0.001). A moderately positive correlation was also found between the maximum diameter of the IVC pre-dialysis and lung USG B-lines (P < 0.001). Lung USG is a promising technique for estimating EVLW in patients on dialysis. Significant correlations between pre-dialysis lung USG B-lines and echocardiographic measures of cardiac function, IVC maximum diameter and edema suggest a link between cardiac performance and volume status. This could complement clinical skills in determining dry weight.

Scientific ReportsVol. 16(1)
Shree Krishna Hospital (IN), Institute of Transplantation Sciences (IN), Pramukhswami Medical College (IN)
Quality Education
Openalex Percentile: Top 81%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.