Insights on Stereoselective Residue and Degradation of Spirotetramat Enantiomers on Tubifex of the Qinghai Plateau

This study established an HPLC-MS/MS method to quantify the enantiomers of spirotetramat in tubifex. To assess the accuracy and precision of the approach, recovery tests were conducted for insecticide. For all enantiomers, the limits of detection were 0.003 mg/kg. The quantization limits were 0.01 mg/kg. Spirotetramat enantiomers recovery rates in tubifex were found to be between 81 and 114%, with relative standard deviations being less than 7%. The half-lives of spirotetramat enantiomers in tubifex were 3.81-10.58 d, respectively. The 22.4% spirotetramat suspension was sprayed on tubifex three times at a low dosage (high dosage advised). After 14 days after harvesting, the terminal residues of spirotetramat enantiomers in the tubifex were less than 0.03 mg/kg. The findings offer a quantitative foundation for setting China's maximum residue limits as well as a recommendation for the safe and responsible usage of spirotetramat enantiomers in tubifex.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2026-01-23
DOI
https://doi.org/10.3390/ijms27031170
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Insights on Stereoselective Residue and Degradation of Spirotetramat Enantiomers on Tubifex of the Qinghai Plateau

Kaifu Zheng, ShuJing Yu, Wei Li, Yang Zhang et al.
International Journal of Molecular Sciences
Pesticide Residue Analysis and Safety
article

Insights on Stereoselective Residue and Degradation of Spirotetramat Enantiomers on Tubifex of the Qinghai Plateau

Kaifu Zheng, ShuJing Yu, Wei Li, Yang Zhang, Shuo Shen
article en

Abstract

This study established an HPLC-MS/MS method to quantify the enantiomers of spirotetramat in tubifex. To assess the accuracy and precision of the approach, recovery tests were conducted for insecticide. For all enantiomers, the limits of detection were 0.003 mg/kg. The quantization limits were 0.01 mg/kg. Spirotetramat enantiomers recovery rates in tubifex were found to be between 81 and 114%, with relative standard deviations being less than 7%. The half-lives of spirotetramat enantiomers in tubifex were 3.81-10.58 d, respectively. The 22.4% spirotetramat suspension was sprayed on tubifex three times at a low dosage (high dosage advised). After 14 days after harvesting, the terminal residues of spirotetramat enantiomers in the tubifex were less than 0.03 mg/kg. The findings offer a quantitative foundation for setting China's maximum residue limits as well as a recommendation for the safe and responsible usage of spirotetramat enantiomers in tubifex.

International Journal of Molecular SciencesVol. 27(3)
Qinghai University (CN), Nankai University (CN), Qinghai Tibetan Hospital (CN), Ministry of Agriculture (ID)
National Natural Science Foundation of China
Openalex Percentile: Top 81%
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.