The influence of keratometry on the accuracy of intraocular lens formulas in highly myopic eyes

To investigate the influence of keratometry on the predictive accuracy of modern IOL formulas in determining optimal IOL power for cataract patients with high myopia. A total of 302 eyes from highly myopic patients who had undergone cataract surgery were divided into subgroups based on axial length AL and K. The predictive outcomes were to compare the accuracy of the following formulas: BU II, EVO 2.0, Haigis, Hoffer Q, Hoffer-QST, Holladay 2, K6, Kane, Pearl-DGS, SRK/T. For each formula, the ME, MAE, MedAE and the percentage of eyes with PEs within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D were analyzed. Among all patients, the Hoffer QST formula achieved the lowest MAE (0.41 D), closely followed by EVO 2.0 (0.42 D). In the axial length subgroups, the Hoffer QST, BU II, and Haigis formulas achieved the lowest MAE (0.35 D) in the long AL group, while K6 achieved the lowest MAE (0.46 D) in the super-long AL group. For the extreme-long AL group, Hoffer QST demonstrated the lowest MAE at 0.41 D, closely followed by EVO 2.0 (0.44 D). In the keratometry subgroups, Hoffer QST consistently showed superior accuracy: in the flat-K group, it attained the lowest MAE (0.35 D) with BU II closely trailing (0.36 D); in the average-K group, it maintained the lowest MAE (0.41 D) followed by EVO 2.0 (0.43 D); and in the steep-K group, it achieved the lowest MAE (0.43 D), closely followed by EVO 2.0 (0.44 D). In highly myopic eyes, modern IOL formulas demonstrate significantly superior predictive accuracy compared to traditional formulas for the different keratometry, with Hoffer QST and EVO 2.0 exhibiting the best performance in this study.

Authors

Institutions

Publication Details

Journal
BMC Ophthalmology
Published
2026-01-22
DOI
https://doi.org/10.1186/s12886-026-04626-x
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The influence of keratometry on the accuracy of intraocular lens formulas in highly myopic eyes

J X Zhang, Zhong-Yan Li, Zhao-Heng Yang, Meng Li et al.
BMC Ophthalmology
Ophthalmology and Visual Impairment Studies
article

The influence of keratometry on the accuracy of intraocular lens formulas in highly myopic eyes

J X Zhang, Zhong-Yan Li, Zhao-Heng Yang, Meng Li, Jie Xu, Xiu-Hua Wan, Peng Zhao, Guang-Yue Li
article en

Abstract

To investigate the influence of keratometry on the predictive accuracy of modern IOL formulas in determining optimal IOL power for cataract patients with high myopia. A total of 302 eyes from highly myopic patients who had undergone cataract surgery were divided into subgroups based on axial length AL and K. The predictive outcomes were to compare the accuracy of the following formulas: BU II, EVO 2.0, Haigis, Hoffer Q, Hoffer-QST, Holladay 2, K6, Kane, Pearl-DGS, SRK/T. For each formula, the ME, MAE, MedAE and the percentage of eyes with PEs within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D were analyzed. Among all patients, the Hoffer QST formula achieved the lowest MAE (0.41 D), closely followed by EVO 2.0 (0.42 D). In the axial length subgroups, the Hoffer QST, BU II, and Haigis formulas achieved the lowest MAE (0.35 D) in the long AL group, while K6 achieved the lowest MAE (0.46 D) in the super-long AL group. For the extreme-long AL group, Hoffer QST demonstrated the lowest MAE at 0.41 D, closely followed by EVO 2.0 (0.44 D). In the keratometry subgroups, Hoffer QST consistently showed superior accuracy: in the flat-K group, it attained the lowest MAE (0.35 D) with BU II closely trailing (0.36 D); in the average-K group, it maintained the lowest MAE (0.41 D) followed by EVO 2.0 (0.43 D); and in the steep-K group, it achieved the lowest MAE (0.43 D), closely followed by EVO 2.0 (0.44 D). In highly myopic eyes, modern IOL formulas demonstrate significantly superior predictive accuracy compared to traditional formulas for the different keratometry, with Hoffer QST and EVO 2.0 exhibiting the best performance in this study.

BMC OphthalmologyVol. 26(1)
Beijing Tongren Hospital (CN), Capital Medical University (CN)
Openalex Percentile: Top 81%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The influence of keratometry on the accuracy of intraocular lens formulas in highly myopic eyes — J X Zhang, Zhong-Yan Li, et al. · BMC Ophthalmology (2026) | TGRS Research Map | TGRS