Initial Design of a Self-Retracting Trocar for Distal Ventriculoperitoneal Catheter Insertion

Background Laparoscopic access, assisted by a general surgeon, is the most commonly used technique for inserting a distal catheter during ventriculoperitoneal shunt placement. This study introduces a novel single-use trocar designed for peritoneal access, combining engineering analyses to ensure performance and safety. Methods We presented the design and bench evaluation of this new trocar concept. A Pugh matrix evaluated material and feature optimization, while failure mode and effect analysis (FMEA) identified risks such as blade dulling and spring failure. Finite element analysis (FEA) confirmed the structural integrity of the trocar. Results The FEA confirmed the structural integrity of the trocar, demonstrating high load capacities of 1655.3 N for the shaft, 503.4 N for the cannula, and 2799.12 N for the handle with minimal deformation and a high safety margin. The prototype features a sharp blade with an automatically retractable blunt tip to reduce tissue trauma and a cannula with a side slit for catheter insertion. Using sausage casing to simulate the peritoneum, sharpness testing showed a breakthrough force of 2.98 N compared to 2 N for the Versastep trocar (Medtronic, Minneapolis, MN). Conclusions The assessment and conceptualization of this new trocar showed reliability, a low risk of component failure, and good sharpness performance after multiple laboratory tests. The self-retractable tip provides a safety profile during insertion into the peritoneal cavity. Further testing in vivo is needed.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-01-22
DOI
https://doi.org/10.7759/cureus.102065
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Initial Design of a Self-Retracting Trocar for Distal Ventriculoperitoneal Catheter Insertion

Jacques Lara‐Reyna, Caleb S. Lee, Julian Lin, Kalyani Nair et al.
Cureus
Cerebrospinal fluid and hydrocephalus
article

Initial Design of a Self-Retracting Trocar for Distal Ventriculoperitoneal Catheter Insertion

Jacques Lara‐Reyna, Caleb S. Lee, Julian Lin, Kalyani Nair, Grant Ganpat, Brendan Mason
article en

Abstract

Background Laparoscopic access, assisted by a general surgeon, is the most commonly used technique for inserting a distal catheter during ventriculoperitoneal shunt placement. This study introduces a novel single-use trocar designed for peritoneal access, combining engineering analyses to ensure performance and safety. Methods We presented the design and bench evaluation of this new trocar concept. A Pugh matrix evaluated material and feature optimization, while failure mode and effect analysis (FMEA) identified risks such as blade dulling and spring failure. Finite element analysis (FEA) confirmed the structural integrity of the trocar. Results The FEA confirmed the structural integrity of the trocar, demonstrating high load capacities of 1655.3 N for the shaft, 503.4 N for the cannula, and 2799.12 N for the handle with minimal deformation and a high safety margin. The prototype features a sharp blade with an automatically retractable blunt tip to reduce tissue trauma and a cannula with a side slit for catheter insertion. Using sausage casing to simulate the peritoneum, sharpness testing showed a breakthrough force of 2.98 N compared to 2 N for the Versastep trocar (Medtronic, Minneapolis, MN). Conclusions The assessment and conceptualization of this new trocar showed reliability, a low risk of component failure, and good sharpness performance after multiple laboratory tests. The self-retractable tip provides a safety profile during insertion into the peritoneal cavity. Further testing in vivo is needed.

CureusVol. 18(1)
Illinois College (US), Bradley University (US)
Good health and well-being
Openalex Percentile: Top 82%
Cerebrospinal fluid and hydrocephalus
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Initial Design of a Self-Retracting Trocar for Distal Ventriculoperitoneal Catheter Insertion — Jacques Lara‐Reyna, Caleb S. Lee, et al. · Cureus (2026) | TGRS Research Map | TGRS