Analysis of Indoor Air Quality in Inpatient Wards using IoT Sensor Data and Machine Learning

Since COVID-19, interest in Indoor Air Quality (IAQ) has increased and research has been conducted on Airborne Infection Isolation Rooms (AIIRs), but more research is needed on long-term IAQ analysis in hospitals. IoT sensors were used to acquire data from Patient Room (PR) and AIIR, and long- term data is used to analyse IAQ. Clustering was performed on target space. Unlike PR and AIIR, Nurse Station (NS) has a full-time occupancy and CO2 concentrations above 1,000 ppm occurred frequently. For temperature, NS, PR, and AIIR all remained within the 23 to 26 °C range, although AIIR occasionally exceeded 30 °C. For PM2.5, the overall average remains below 20 μg/m3 in NS, PR, and AIIR. However, it remained largely unchanged in NS, but sharp events with concentrations above 100 μg/m3 occurred frequently in PR and AIIR. The overall PM2.5 concentrations were well maintained, but the frequent PM2.5 peak concentrations were very high for short periods of time and need to be further managed. IoT sensors can be utilized to acquire continuous IAQ data in wards. IAQ management is required through continuous measurement using IoT sensors. The large amount of IAQ data acquired can be utilized in various ways by applying machine learning.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-01-21
DOI
https://doi.org/10.1051/e3sconf/202668905003/pdf
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Indoor Air Quality in Inpatient Wards using IoT Sensor Data and Machine Learning

Jehyun Kim, Ji-Hi Kim, Minki Sung
Springer Link (Chiba Institute of Technology)
Indoor Air Quality and Microbial Exposure
article

Analysis of Indoor Air Quality in Inpatient Wards using IoT Sensor Data and Machine Learning

Jehyun Kim, Ji-Hi Kim, Minki Sung
article en

Abstract

Since COVID-19, interest in Indoor Air Quality (IAQ) has increased and research has been conducted on Airborne Infection Isolation Rooms (AIIRs), but more research is needed on long-term IAQ analysis in hospitals. IoT sensors were used to acquire data from Patient Room (PR) and AIIR, and long- term data is used to analyse IAQ. Clustering was performed on target space. Unlike PR and AIIR, Nurse Station (NS) has a full-time occupancy and CO2 concentrations above 1,000 ppm occurred frequently. For temperature, NS, PR, and AIIR all remained within the 23 to 26 °C range, although AIIR occasionally exceeded 30 °C. For PM2.5, the overall average remains below 20 μg/m3 in NS, PR, and AIIR. However, it remained largely unchanged in NS, but sharp events with concentrations above 100 μg/m3 occurred frequently in PR and AIIR. The overall PM2.5 concentrations were well maintained, but the frequent PM2.5 peak concentrations were very high for short periods of time and need to be further managed. IoT sensors can be utilized to acquire continuous IAQ data in wards. IAQ management is required through continuous measurement using IoT sensors. The large amount of IAQ data acquired can be utilized in various ways by applying machine learning.

Springer Link (Chiba Institute of Technology)
Korea Disease Control and Prevention Agency
Openalex Percentile: Top 82%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.