The Role of Reinforcement Density in the Capacitance Based Self-Sensing Behavior of Concrete Elements

This study explores the self-sensing capabilities of reinforced concrete elements with a coplanar electrode system, without using conductive fillers. Specimens with different tensile reinforcement amounts (2 and 4 bars) were subjected to four-point tensile loading, and capacitance was measured throughout the process. The initial (with no load) capacitance value for the element with two tensile reinforcements was approximately 215 pF, and for the element with four tensile reinforcements, it was 282 pF. Capacitance decreased with increasing vertical beam deflection, with the reduction more pronounced as the load and reinforcement density increased. At loads of 36 and 72 kN, capacitance reduction was 39% for the two-reinforcement specimen and 49% for the four-reinforcement specimen. Stress sensitivity was approximately 1.92×10−8 Pa−1, indicating minimal influence of reinforcement density at low loading levels (0–20 kN). The study confirms that reinforced concrete elements have inherent self-sensing capabilities for stress and deformation, regardless of reinforcement density. Capacitance-based monitoring systems were shown to be effective for detecting microstructural changes, offering a promising method for real-time structural health monitoring in critical infrastructure.

Authors

Institutions

Publication Details

Journal
Journal of Materials in Civil Engineering
Published
2026-01-22
DOI
https://doi.org/10.1061/jmcee7.mteng-21529
Primary Topic
Smart Materials for Construction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Role of Reinforcement Density in the Capacitance Based Self-Sensing Behavior of Concrete Elements

A. Caglayan, Murat Ozturk
Journal of Materials in Civil Engineering
Smart Materials for Construction
article

The Role of Reinforcement Density in the Capacitance Based Self-Sensing Behavior of Concrete Elements

A. Caglayan, Murat Ozturk
article en

Abstract

This study explores the self-sensing capabilities of reinforced concrete elements with a coplanar electrode system, without using conductive fillers. Specimens with different tensile reinforcement amounts (2 and 4 bars) were subjected to four-point tensile loading, and capacitance was measured throughout the process. The initial (with no load) capacitance value for the element with two tensile reinforcements was approximately 215 pF, and for the element with four tensile reinforcements, it was 282 pF. Capacitance decreased with increasing vertical beam deflection, with the reduction more pronounced as the load and reinforcement density increased. At loads of 36 and 72 kN, capacitance reduction was 39% for the two-reinforcement specimen and 49% for the four-reinforcement specimen. Stress sensitivity was approximately 1.92×10−8 Pa−1, indicating minimal influence of reinforcement density at low loading levels (0–20 kN). The study confirms that reinforced concrete elements have inherent self-sensing capabilities for stress and deformation, regardless of reinforcement density. Capacitance-based monitoring systems were shown to be effective for detecting microstructural changes, offering a promising method for real-time structural health monitoring in critical infrastructure.

Journal of Materials in Civil EngineeringVol. 38(4)
Bursa Uludağ Üni̇versi̇tesi̇ (TR)
Industry, innovation and infrastructure
Openalex Percentile: Top 82%
Smart Materials for Construction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.