Economic dispatch optimization of a metal hydride storage system for supplying heat and electricity in a residential application

To achieve affordable, clean energy, incorporating renewable energy into existing energy systems is the key. One challenge is the fluctuating nature of renewable resources, which can be asynchronous with energy demands. Hydrogen storage, particularly metal hydride storage, is a favorable solution for balancing supply and demand. In particular, metal hydride storage, compared with pressurized or liquefied hydrogen storage, is a favorable technology choice due to its storage energy density (50-100 kg H˙2/m 3 ) and its low operating temperature and pressure. This paper presents a simulation-based framework to investigate the optimal design and operation of a coupled Electrolyzer-Fuel Cell-Metal Hydride system (SET-Unit) for minimizing operational and capital expenses in a residential application. The results show that integrating heat pumps with a metal-hydride storage system and photovoltaics can achieve 83% energy self-sufficiency and a 7.1-year payback period. Combining SET-Unit, gas boilers, and photovoltaics can result in 28% energy self-sufficiency, annual savings of over 2221 EUR, and a payback period of 7.4 years. The SET-Unit, combined with renewable energy sources such as photovoltaics, and the in-market available gas boilers or heat pumps, shows benefits in efficiency, annual energy cost reduction, and a relatively short payback period for the household. Using the low end of published values for capital expenses, economic feasibility can be achieved. • Simulation-based framework to minimize metal-hydride storage systems costs. • SET-Unit and heat pump systems increase the self-sufficiency to 83%. • SET-Unit and gas boiler systems increase the self-sufficiency to 28%. • SET-Unit and heat pump systems can save 255 EUR in energy costs annually. • SET-Unit and heat pump systems have a payback period of 7.1 years.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management X
Published
2026-01-21
DOI
https://doi.org/10.1016/j.ecmx.2026.101579
Primary Topic
Hydrogen Storage and Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Economic dispatch optimization of a metal hydride storage system for supplying heat and electricity in a residential application

Julián Puszkiel, Michael Kroener, Julian Jepsen, Nies Reininghaus et al.
Energy Conversion and Management X
Hydrogen Storage and Materials
article

Economic dispatch optimization of a metal hydride storage system for supplying heat and electricity in a residential application

Julián Puszkiel, Michael Kroener, Julian Jepsen, Nies Reininghaus, Carlos Muñoz, Astrid Pistoor, Thomas Klassen, Martin Vehse, Alexander Dyck
article en

Abstract

To achieve affordable, clean energy, incorporating renewable energy into existing energy systems is the key. One challenge is the fluctuating nature of renewable resources, which can be asynchronous with energy demands. Hydrogen storage, particularly metal hydride storage, is a favorable solution for balancing supply and demand. In particular, metal hydride storage, compared with pressurized or liquefied hydrogen storage, is a favorable technology choice due to its storage energy density (50-100 kg H˙2/m 3 ) and its low operating temperature and pressure. This paper presents a simulation-based framework to investigate the optimal design and operation of a coupled Electrolyzer-Fuel Cell-Metal Hydride system (SET-Unit) for minimizing operational and capital expenses in a residential application. The results show that integrating heat pumps with a metal-hydride storage system and photovoltaics can achieve 83% energy self-sufficiency and a 7.1-year payback period. Combining SET-Unit, gas boilers, and photovoltaics can result in 28% energy self-sufficiency, annual savings of over 2221 EUR, and a payback period of 7.4 years. The SET-Unit, combined with renewable energy sources such as photovoltaics, and the in-market available gas boilers or heat pumps, shows benefits in efficiency, annual energy cost reduction, and a relatively short payback period for the household. Using the low end of published values for capital expenses, economic feasibility can be achieved. • Simulation-based framework to minimize metal-hydride storage systems costs. • SET-Unit and heat pump systems increase the self-sufficiency to 83%. • SET-Unit and gas boiler systems increase the self-sufficiency to 28%. • SET-Unit and heat pump systems can save 255 EUR in energy costs annually. • SET-Unit and heat pump systems have a payback period of 7.1 years.

Energy Conversion and Management XVol. 30
Carl von Ossietzky Universität Oldenburg (DE), Helmut Schmidt University (DE), Helmholtz-Zentrum Hereon (DE)
Industry, innovation and infrastructure
Openalex Percentile: Top 81%
Hydrogen Storage and Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.