Is there a need to modify the anatomical targets for genicular nerve ablation in prosthetic knees compared with native knees? A cadaveric study
Prosthetic knees share comparable genicular nerve anatomic locations with native knees but exhibit smaller nerve diameters and fibrosis of the IPBSN. The absence of a nearby arterial branch to the SLGN may reduce ultrasound targeting accuracy. Anatomical differences alone, however, do not fully explain the diminished pain relief observed after radiofrequency ablation.
Authors
- Catherine Behets (ORCID: https://orcid.org/0000-0003-0468-7076)
- Loïc Fonkoué (ORCID: https://orcid.org/0000-0002-4209-9163)
- Fodjeu Gaspary
- Cedric Dongmo Mayopa
- Olivier Cornu
- Julie Manon
Institutions
- Cliniques Universitaires Saint-Luc (BE)
- UCLouvain (BE)
Publication Details
- Journal
- Regional Anesthesia & Pain Medicine
- Published
- 2026-01-22
- DOI
- https://doi.org/10.1136/rapm-2025-107379
- Primary Topic
- Total Knee Arthroplasty Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00