Blank Spectrum Correction as a Robust Solution to Artifacts in Quantitative X-ray Fluorescence Mapping

X-ray fluorescence microscopy (XFM) continues to develop as a powerful quantitative technique for high resolution, label-free, elemental mapping of biological, environmental, and material samples. Methods for rigorously fitting spectra, increasing throughput, accounting for background signals, and deconvoluting overlapping emission lines continue to evolve. We show here that quantitative fits of XFM data obtained after removing a baseline, calculated by connecting peak edges, can be unexpectedly dependent upon acquisition dwell-time and spectral aggregation leading to differences in apparent elemental content. Using mouse preimplantation embryos and ovarian follicles as model samples, we demonstrate how these variables influence quantitative comparisons between samples. We find that subtracting an empirically measured blank spectrum instead of a baseline provides quantitative XFM elemental mapping results that are independent of dwell time and spectral aggregation dependencies.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-01-21
DOI
https://doi.org/10.64898/2026.01.18.700193
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Blank Spectrum Correction as a Robust Solution to Artifacts in Quantitative X-ray Fluorescence Mapping

T. O’Halloran, Teresa K. Woodruff, Seth A. Garwin, Thomas V. O’Halloran et al.
bioRxiv (Cold Spring Harbor Laboratory)
Advanced X-ray Imaging Techniques
article

Blank Spectrum Correction as a Robust Solution to Artifacts in Quantitative X-ray Fluorescence Mapping

T. O’Halloran, Teresa K. Woodruff, Seth A. Garwin, Thomas V. O’Halloran, Qi Jin, James E Penner-Hahn, Chris Jacobsen, Julia Balough, Yu-Ying Chen, Andrew McCarten Crawford
article en

Abstract

X-ray fluorescence microscopy (XFM) continues to develop as a powerful quantitative technique for high resolution, label-free, elemental mapping of biological, environmental, and material samples. Methods for rigorously fitting spectra, increasing throughput, accounting for background signals, and deconvoluting overlapping emission lines continue to evolve. We show here that quantitative fits of XFM data obtained after removing a baseline, calculated by connecting peak edges, can be unexpectedly dependent upon acquisition dwell-time and spectral aggregation leading to differences in apparent elemental content. Using mouse preimplantation embryos and ovarian follicles as model samples, we demonstrate how these variables influence quantitative comparisons between samples. We find that subtracting an empirically measured blank spectrum instead of a baseline provides quantitative XFM elemental mapping results that are independent of dwell time and spectral aggregation dependencies.

bioRxiv (Cold Spring Harbor Laboratory)
Northwestern University (US), University of Michigan (US), Michigan State University (US)
U.S. Department of Energy, Michigan State University, Office of Science, College of Engineering, Michigan State University, Argonne National Laboratory
Life in Land
Openalex Percentile: Top 80%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.