Thermal performance evaluation of double-skin façade in mid-rise wooden building based on field measurement

The thermal performance of a double-skin façade in Japan’s first mid-rise purely wooden fire- resistant building was evaluated through a year-long field survey. In October, the solar heat gain coefficient for the entire window was measured at 0.46 with the blinds open and 0.11 when the blinds were closed. The design featured a wooden frame structure with a large volume and an offset inner skin layer, which helped shade the inner glazing from May to August. The wooden columns and beams exhibited high thermal performance even without thermal insulation, with a thermal transmittance of 0.22 W/(m²·K), accounting for the effects of the double-skin layer. In contrast, the single-skin façade on the 8th floor, made of Low-E double glazing, had a thermal transmittance of 1.85 W/(m²·K). The overall thermal transmittance for the whole window of the double-skin façade on the 4th floor was recorded at 1.66 W/(m²·K).

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-01-21
DOI
https://doi.org/10.1051/e3sconf/202668904005/pdf
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal performance evaluation of double-skin façade in mid-rise wooden building based on field measurement

Yohei Moriyama, Masato Ikeda, Takuji Yasuda, Junta Nakano
Springer Link (Chiba Institute of Technology)
Building Energy and Comfort Optimization
article

Thermal performance evaluation of double-skin façade in mid-rise wooden building based on field measurement

Yohei Moriyama, Masato Ikeda, Takuji Yasuda, Junta Nakano
article en

Abstract

The thermal performance of a double-skin façade in Japan’s first mid-rise purely wooden fire- resistant building was evaluated through a year-long field survey. In October, the solar heat gain coefficient for the entire window was measured at 0.46 with the blinds open and 0.11 when the blinds were closed. The design featured a wooden frame structure with a large volume and an offset inner skin layer, which helped shade the inner glazing from May to August. The wooden columns and beams exhibited high thermal performance even without thermal insulation, with a thermal transmittance of 0.22 W/(m²·K), accounting for the effects of the double-skin layer. In contrast, the single-skin façade on the 8th floor, made of Low-E double glazing, had a thermal transmittance of 1.85 W/(m²·K). The overall thermal transmittance for the whole window of the double-skin façade on the 4th floor was recorded at 1.66 W/(m²·K).

Springer Link (Chiba Institute of Technology)
Sustainable cities and communities
Openalex Percentile: Top 81%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.