Large Language Models in Radiologic Numerical Tasks: A Thorough Evaluation and Error Analysis

The purpose of this study was to investigate the performance of LLMs in radiology numerical tasks and perform a comprehensive error analysis. We defined six tasks: extracting (1) minimum T-score from DEXA report, (2) maximum common bile duct (CBD) diameter from ultrasound report, and (3) maximum lung nodule size from CT report, and judging (1) presence of a highly hypermetabolic region on a PET report, (2) whether a patient is osteoporotic based on a DEXA report, and (3) whether a patient has a dilated CBD based on an ultrasound report. Reports were extracted from the MIMIC III and our institution's databases, and the ground truths were extracted manually. The models used were Llama 3.1 8b, DeepSeek R1 distilled Llama 8b, OpenAI o1-mini, and OpenAI GPT-5-mini. We manually reviewed all incorrect outputs and performed a comprehensive error analysis. In extraction tasks, while Llama showed relatively variable results (ranging 86%-98.7%) across tasks, other models performed consistently well (accuracies > 95%). In judgment tasks, the lowest accuracies of Llama, DeepSeek distilled Llama, o1-mini, and GPT-5-mini were 62.0%, 91.7%, 91.7%, and 99.0%, respectively, while o1-mini and GPT-5-mini did reach 100% performance in detecting osteoporosis. We found no mathematical errors in the outputs of o1-mini and GPT-5-mini. Answer-only output format significantly reduced performance in Llama and DeepSeek distilled Llama but not in o1-mini or GPT-5-mini. To conclude, reinforcement learning (RL) reasoning models perform consistently well in radiology numerical tasks and show no mathematical errors. Simpler non-RL reasoning models may also achieve acceptable performance depending on the task.

Authors

Institutions

Publication Details

Journal
Journal of Imaging Informatics in Medicine
Published
2026-01-21
DOI
https://doi.org/10.1007/s10278-025-01824-9
Citations
1
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
17.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Large Language Models in Radiologic Numerical Tasks: A Thorough Evaluation and Error Analysis

Adrian Serapio, Masha Bondarenko, Tician Schnitzler, Jae Ho Sohn et al.
1 citations
Journal of Imaging Informatics in Medicine
Artificial Intelligence in Healthcare and Education
17.70
article

Large Language Models in Radiologic Numerical Tasks: A Thorough Evaluation and Error Analysis

Adrian Serapio, Masha Bondarenko, Tician Schnitzler, Jae Ho Sohn, Sukhmanjit S. Brar, Ali Nowroozi
article en
1 citations

Abstract

The purpose of this study was to investigate the performance of LLMs in radiology numerical tasks and perform a comprehensive error analysis. We defined six tasks: extracting (1) minimum T-score from DEXA report, (2) maximum common bile duct (CBD) diameter from ultrasound report, and (3) maximum lung nodule size from CT report, and judging (1) presence of a highly hypermetabolic region on a PET report, (2) whether a patient is osteoporotic based on a DEXA report, and (3) whether a patient has a dilated CBD based on an ultrasound report. Reports were extracted from the MIMIC III and our institution's databases, and the ground truths were extracted manually. The models used were Llama 3.1 8b, DeepSeek R1 distilled Llama 8b, OpenAI o1-mini, and OpenAI GPT-5-mini. We manually reviewed all incorrect outputs and performed a comprehensive error analysis. In extraction tasks, while Llama showed relatively variable results (ranging 86%-98.7%) across tasks, other models performed consistently well (accuracies > 95%). In judgment tasks, the lowest accuracies of Llama, DeepSeek distilled Llama, o1-mini, and GPT-5-mini were 62.0%, 91.7%, 91.7%, and 99.0%, respectively, while o1-mini and GPT-5-mini did reach 100% performance in detecting osteoporosis. We found no mathematical errors in the outputs of o1-mini and GPT-5-mini. Answer-only output format significantly reduced performance in Llama and DeepSeek distilled Llama but not in o1-mini or GPT-5-mini. To conclude, reinforcement learning (RL) reasoning models perform consistently well in radiology numerical tasks and show no mathematical errors. Simpler non-RL reasoning models may also achieve acceptable performance depending on the task.

Journal of Imaging Informatics in Medicine
University of California, San Francisco (US), All India Institute of Medical Sciences Bhopal (IN)
Peace, Justice and strong institutions
Openalex Percentile: Top 2%
Artificial Intelligence in Healthcare and Education
17.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.