Two-lens telecentric model eyes for image distortion measurement in adaptive optics ophthalmoscopes

Here we present the design of telecentric model eyes for measuring image distortion in adaptive optics ophthalmoscopes, using pairs of achromatic or near-achromatic commercial off-the-shelf (COTS) and/or custom doublet lenses. The proposed model eyes can operate over visible or visible plus near infrared wavelength ranges, across a 15-diopter focus range, with an 8 mm entrance pupil diameter. COTS lens selection was implemented as a systematic evaluation of catalog lenses after optimization of axial distances. Custom lens optimization was initially guided by wavefront aberration constraints derived from object-shift 3<sup>rd</sup> order aberration theory, before traditional variation of surfaces and distances to minimize a performance metric. When a wavefront corrector compensates for field-constant aberrations, the model eyes achieve nominal wavefront RMS below λ/20 across a ∼6.9° circular full field of view for COTS and hybrid lens pairs, limited by vignetting from a self-imposed 27.9 mm clear aperture. For custom lens pairs, the field of view is about 10.2°, limited by aberrations. A tolerance study indicates that a COTS lens pair for 450-1100 nm can achieve as-built diffraction-limited wavefront error of 0.044 λ @450 nm at 95% production yield. Model eyes with this lens pair yielded telecentricity quantified as image size changed per diopter of 0.1%/D when assembled with a camera and 0.01%/D when assembled with a power meter. The model eye was tested with an optical setup that emulates a fundus camera with Badal focus correction.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2026-01-22
DOI
https://doi.org/10.1364/boe.582188
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-lens telecentric model eyes for image distortion measurement in adaptive optics ophthalmoscopes

Gastón A. Ayubi, Julie Bentley, Alfredo Dubra, Yuning Xia
Biomedical Optics Express
Ophthalmology and Visual Impairment Studies
article

Two-lens telecentric model eyes for image distortion measurement in adaptive optics ophthalmoscopes

Gastón A. Ayubi, Julie Bentley, Alfredo Dubra, Yuning Xia
article en

Abstract

Here we present the design of telecentric model eyes for measuring image distortion in adaptive optics ophthalmoscopes, using pairs of achromatic or near-achromatic commercial off-the-shelf (COTS) and/or custom doublet lenses. The proposed model eyes can operate over visible or visible plus near infrared wavelength ranges, across a 15-diopter focus range, with an 8 mm entrance pupil diameter. COTS lens selection was implemented as a systematic evaluation of catalog lenses after optimization of axial distances. Custom lens optimization was initially guided by wavefront aberration constraints derived from object-shift 3<sup>rd</sup> order aberration theory, before traditional variation of surfaces and distances to minimize a performance metric. When a wavefront corrector compensates for field-constant aberrations, the model eyes achieve nominal wavefront RMS below λ/20 across a ∼6.9° circular full field of view for COTS and hybrid lens pairs, limited by vignetting from a self-imposed 27.9 mm clear aperture. For custom lens pairs, the field of view is about 10.2°, limited by aberrations. A tolerance study indicates that a COTS lens pair for 450-1100 nm can achieve as-built diffraction-limited wavefront error of 0.044 λ @450 nm at 95% production yield. Model eyes with this lens pair yielded telecentricity quantified as image size changed per diopter of 0.1%/D when assembled with a camera and 0.01%/D when assembled with a power meter. The model eye was tested with an optical setup that emulates a fundus camera with Badal focus correction.

Biomedical Optics ExpressVol. 17(2)
University of Rochester (US), Smith-Kettlewell Eye Research Institute (US), Stanford University (US)
Openalex Percentile: Top 81%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.