Quantitative Prediction of Human Pharmacokinetics for Fc‐Engineered Therapeutic Monoclonal Antibodies With Increased <scp>FcRn</scp> Binding Mutations After Subcutaneous Injection

Fc-engineered antibodies (mAbs) enhancing FcRn binding have rapidly expanded in drug discovery and development. Although an approach exists for predicting the pharmacokinetics of Fc-engineered mAbs after intravenous injections in humans, no methodology has been established for predicting pharmacokinetics after subcutaneous injections. This study aimed to establish a methodology for predicting the pharmacokinetics of Fc-engineered mAbs after subcutaneous injections in humans. First, bioavailability (F) and absorption rate constant (k<sub>a</sub>) values following subcutaneous injections in humans were collected and analyzed. Then, AUC after subcutaneous injections in humans was predicted using the geometric mean of reported F and allometrically scaled clearance (CL) from cynomolgus monkeys. Next, plasma concentration-time profiles after subcutaneous injections were predicted using the geometric mean of reported F and k<sub>a</sub> values and allometrically scaled two-compartment model parameters from cynomolgus monkeys. The geometric mean of reported F for Fc-engineered mAbs in humans was 0.601, lower than that of normal mAbs. The geometric mean of ka was 0.284/day, comparable to normal mAbs. The prediction accuracy of AUC using the geometric mean of F and scaled CL from cynomolgus monkeys was 95.2% within 2-fold of observed values. Furthermore, C<sub>max</sub> and T<sub>max</sub> after subcutaneous injections showed 94.1% and 70.6% prediction accuracy within 2-fold of observed values, respectively. Overall, 88.4% and 95.3% of whole plasma concentration-time profiles were predicted within 2-fold and 3-fold of observed values, respectively, demonstrating the high prediction accuracy. This methodology, combining fixed absorption parameters with scaled two-compartment model parameters, can significantly support Fc-engineered mAbs development.

Authors

Institutions

Publication Details

Journal
Clinical and Translational Science
Published
2026-01-22
DOI
https://doi.org/10.1111/cts.70482
Citations
1
Primary Topic
Monoclonal and Polyclonal Antibodies Research
Type
article
Field-Weighted Citation Impact
31.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Prediction of Human Pharmacokinetics for Fc‐Engineered Therapeutic Monoclonal Antibodies With Increased FcRn Binding Mutations After Subcutaneous Injection

Kenta Haraya, Taichi Kuramochi
1 citations
Clinical and Translational Science
Monoclonal and Polyclonal Antibodies Research
31.92
article

Quantitative Prediction of Human Pharmacokinetics for Fc‐Engineered Therapeutic Monoclonal Antibodies With Increased FcRn Binding Mutations After Subcutaneous Injection

Kenta Haraya, Taichi Kuramochi
article en
1 citations

Abstract

Fc-engineered antibodies (mAbs) enhancing FcRn binding have rapidly expanded in drug discovery and development. Although an approach exists for predicting the pharmacokinetics of Fc-engineered mAbs after intravenous injections in humans, no methodology has been established for predicting pharmacokinetics after subcutaneous injections. This study aimed to establish a methodology for predicting the pharmacokinetics of Fc-engineered mAbs after subcutaneous injections in humans. First, bioavailability (F) and absorption rate constant (k<sub>a</sub>) values following subcutaneous injections in humans were collected and analyzed. Then, AUC after subcutaneous injections in humans was predicted using the geometric mean of reported F and allometrically scaled clearance (CL) from cynomolgus monkeys. Next, plasma concentration-time profiles after subcutaneous injections were predicted using the geometric mean of reported F and k<sub>a</sub> values and allometrically scaled two-compartment model parameters from cynomolgus monkeys. The geometric mean of reported F for Fc-engineered mAbs in humans was 0.601, lower than that of normal mAbs. The geometric mean of ka was 0.284/day, comparable to normal mAbs. The prediction accuracy of AUC using the geometric mean of F and scaled CL from cynomolgus monkeys was 95.2% within 2-fold of observed values. Furthermore, C<sub>max</sub> and T<sub>max</sub> after subcutaneous injections showed 94.1% and 70.6% prediction accuracy within 2-fold of observed values, respectively. Overall, 88.4% and 95.3% of whole plasma concentration-time profiles were predicted within 2-fold and 3-fold of observed values, respectively, demonstrating the high prediction accuracy. This methodology, combining fixed absorption parameters with scaled two-compartment model parameters, can significantly support Fc-engineered mAbs development.

Clinical and Translational ScienceVol. 19(2)
Chugai Pharma (United States) (US)
Chugai Pharmaceutical
Good health and well-being
Openalex Percentile: Top 2%
Monoclonal and Polyclonal Antibodies Research
31.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.