Editorial: Innovative approaches in precision radiation oncology

Advancing spatially fractionated radiotherapy, Ma et al. introduced an optimization framework for determining vertex placement in lattice radiotherapy using closest packing combined with adaptive simulated annealing. Their method significantly increased the peak-to-valley dose contrast, with the optimized plans demonstrating a nearly six-fold improvement in peak-to-valley index compared with conventional packing approaches, highlighting a reproducible and automated strategy to enhance treatment precision for bulky tumors. Complementing this work on spatial dose modulation, Li et al. evaluated proton-based stereotactic centralized/core ablative radiation therapy (pSCART) in a treatment planning study of bulky tumors. By leveraging the physical dose advantages of protons, pSCART enabled higher prescription doses (24 Gy × 3 fractions) and improved high-dose central coverage while reducing dose spill at the tumor periphery and lowering mean doses to surrounding OARs compared with photon-based SCART techniques, supporting its potential for future clinical translation. Also, contributions focused on optimization of volumetric modulated arc therapy (VMAT) planning parameters to improve OAR protection without compromising target coverage. Guo et al. demonstrated that careful adjustment of physical parameters in a knowledge-based partial-arc VMAT RapidPlan model for left-sided breast cancer significantly reduced doses to the heart, lungs, and contralateral breast, emphasizing the importance of aligning model configuration with delivery geometry to mitigate low-dose exposure and secondary cancer risk. In a related dosimetric study, Huang et al. showed that incorporating orthogonal collimator angles (0°/90°) in dual-arc VMAT improved conformity, dose gradient, and OAR sparing across head-and-neck, thoracic, and pelvic sites, with all plans maintaining high delivery accuracy, demonstrating a simple yet effective planning refinement applicable in routine practice. Optimization of biological and clinical dose constraints was further explored by Hu et al., who investigated the use of the Monaco serial biological function for cardiac dose optimization in deep-inspiration breath-hold IMRT for leftsided breast cancer. Their analysis identified an optimal K-value range (2-4) that achieved balanced reduction in mean and maximum cardiac and coronary artery doses while preserving target coverage, providing evidence-based guidance for biologically informed planning parameter selection. Innovations in system-specific planning were also highlighted. Tang et al. developed a hippocampal-sparing whole-brain radiotherapy planning approach using the Halcyon platform with coplanar dual-arc VMAT and target substructure segmentation. Compared with conventional systems, this strategy achieved improved dose homogeneity, reduced hippocampal dose and normal tissue complication probability, and high gamma passing rates, demonstrating that advanced planning techniques can enhance neurocognitive preservation without increasing workflow complexity. Furthermore, clinical feasibility of advanced planning and delivery workflows was reinforced by Sun et al., who evaluated fan-beam CT-guided online adaptive replanning in definitive cervical cancer radiotherapy. Across 278 adaptive fractions, their approach consistently improved target coverage and OAR sparing with a mean gamma passing rate exceeding 99% and a clinically acceptable workflow duration of approximately 23 minutes, underscoring how optimized planning and delivery strategies can be successfully integrated into routine clinical practice. In the context of rare pediatric tumors, Zhang et al. reported a multimodal precision treatment strategy for MN1-altered astroblastoma, demonstrating how the tissue-sparing advantages of proton beam therapy can facilitate effective salvage Gamma Knife radiosurgery while maintaining durable local control and minimal toxicity.2. Imaging, Dosimetry, and Verification: Advanced imaging, quantitative dosimetry, and rigorous verification are foundational to precision radiation oncology, enabling accurate target definition, reliable dose delivery, and safe clinical implementation of increasingly complex treatment techniques. Six contributions in this Research Topic addressed these themes across clinical, technical, and preclinical domains, highlighting how imaging and verification strategies directly influence treatment accuracy, toxicity, and translational reliability.Several studies focused on dosimetric characterization and verification of complex delivery techniques. Wang et al. performed a comprehensive dosimetric and efficiency comparison between TomoDirect and TomoHelical radiotherapy for total skin irradiation. Their analysis demonstrated that TomoDirect plans using more than nine beams achieved target coverage, homogeneity, and organ-at-risk sparing comparable to TomoHelical delivery, while maintaining similar treatment times when appropriate auxiliary structure blocking was applied. These findings provide practical guidance for modality selection and protocol design in total skin irradiation, where large treatment volumes and delivery efficiency are critical. Quantitative assessment of dose delivery accuracy and verification was further advanced by Zhou et al., who developed a lightweight Swin-Transformer-based deep learning framework for patient-specific VMAT delivered-dose prediction. Their model achieved high structural similarity and gamma passing rates relative to ground truth dose distributions, while substantially reducing model complexity compared with existing transformer architectures. This work highlights the growing role of artificial intelligence in patient-specific quality assurance, offering a scalable and clinically viable alternative to labor-intensive measurement-based verification workflows. The role of imaging in refining dosimetric evaluation and treatment response assessment was addressed in multiple contributions. Qian et al. analyzed quantitative imaging features derived from 18 F-DOPA PET in glioblastoma patients treated with dose-escalated radiotherapy. Their results demonstrated that pretreatment imaging signatures and early post-treatment changes could stratify survival outcomes in MGMT-unmethylated tumors and identify patients most likely to benefit from dose escalation. This study underscores the potential of functional imaging biomarkers to inform both dosimetric decision-making and adaptive treatment strategies. Similarly, Borowiec et al. evaluated the clinical value of extended baseline cross-sectional imaging in locally advanced high-risk breast cancer. By incorporating CT or PET-CT into initial staging, the authors showed that disease stage and radiation treatment planning were altered in a substantial proportion of patients, enabling highly customized dose delivery to surgically inaccessible nodal regions. Their findings emphasize that imaging choice at baseline can directly impact dosimetric strategy and treatment individualization. Geometric sensitivity and setup-related dose variation were examined by Xiao et al., who conducted a propensity-matched cohort study comparing supine and prone positioning in postoperative cervical cancer radiotherapy. While target coverage remained comparable, positioning significantly influenced organ dose distributions, setup error profiles, and acute toxicity patterns. This work highlights how verification of geometric and positional factors is integral to optimizing both dosimetry and clinical safety in pelvic radiotherapy. Finally, Tavakkoli et al. addressed verification and biological confounding factors in the preclinical evaluation of ultra-high dose-rate (FLASH) radiotherapy. Using a murine total abdominal irradiation model, they demonstrated that anesthetic-dependent tissue oxygenation critically determined the presence or absence of FLASH sparing. Their findings underscore the importance of rigorous control and reporting of physiological variables when verifying dose-response relationships, particularly for emerging technologies poised for clinical translation.Collectively, these studies demonstrate that precision radiation oncology relies not only on sophisticated planning and delivery techniques, but also on robust imaging, dosimetric evaluation, and verification frameworks. By integrating quantitative imaging, advanced computational verification, and careful assessment of geometric and biological uncertainties, these contributions provide essential foundations for safe, accurate, and personalized radiotherapy.The transition from advanced treatment concepts to routine clinical practice represents a critical step in precision radiation oncology. Three contributions within this Research Topic focused on adaptive and online radiotherapy workflows, emphasizing real-time plan adaptation, clinical feasibility, and practical considerations for implementation in busy treatment environments.Anchoring this theme, the technical feasibility of optimized planning and delivery was supported by Sun et al., who demonstrated high-accuracy fan-beam CT-guided online adaptive replanning in definitive cervical cancer radiotherapy, achieving consistent target coverage and organ-at-risk sparing across 278 fractions within a clinically acceptable workflow time. Building on this foundation, Asher et al. examined broader aspects of clinical implementation, focusing on workflow translation and operational considerations associated with adaptive radiotherapy adoption. Their study addressed practical challenges such as staffing, training, and integration of adaptive processes within existing clinical infrastructures, highlighting that successful implementation depends not only on technical capability but also on multidisciplinary coordination and institutional readiness. Complementing these perspectives, Pang et al. explored clinical adaptation strategies aimed at tailoring treatment delivery to patient-specific and time-varying anatomical changes. Their work emphasized decision-making frameworks for when and how to adapt treatment plans, underscoring the importance of balancing dosimetric benefit with workflow efficiency and clinical resource utilization.Collectively, these studies demonstrate that adaptive radiotherapy has progressed beyond proofof-concept, with emerging evidence supporting its safe and effective deployment in clinical practice (Yan et al.). By addressing real-time adaptation, workflow feasibility, and implementation strategy, these contributions provide a roadmap for translating adaptive radiotherapy technologies into routine patient care and advancing the clinical impact of precision radiation oncology.A defining challenge in precision radiation oncology is understanding how identical physical dose prescriptions can produce markedly different biological and clinical outcomes across patients. Several contributions in this Research Topic addressed this challenge by examining immune signaling pathways, tumor-microenvironment interactions, and biological predictors of treatment response, highlighting the importance of integrating molecular biology into radiation treatment paradigms.Xiong et al. provided a comprehensive mini-review of the cGAS-STING signaling pathway as a central mediator linking radiation-induced DNA damage to innate and adaptive immune activation in breast cancer. The authors emphasized the dual and subtype-dependent roles of cGAS-STING signaling, demonstrating that acute pathway activation can enhance antitumor immunity and radiosensitization, whereas chronic or dysregulated activation may promote immunosuppression, regulatory T-cell expansion, and therapeutic resistance. By integrating molecular mechanisms with emerging translational and clinical considerations across luminal, HER2-positive, and triple-negative breast cancer subtypes, this work underscores the need for subtype-specific immune modulation strategies when designing radiation-immunotherapy combinations.Complementing immune-centric mechanisms, Keepers et al. investigated biological response modulation using mouse pancreatic tumor organoids as a translational preclinical platform. Their study demonstrated that combining low-dose chemotherapy with fractionated radiation produced significantly greater tumor growth inhibition than either modality alone. This enhanced effect was associated with increased DNA damage signaling, elevated reactive oxygen species production, and suppression of mesenchymal markers, supporting the concept that biologically informed combination strategies can amplify radiation efficacy while potentially reducing treatment-related toxicity. The use of tumor-derived organoids further highlights the value of advanced biological models for evaluating radiation-drug interactions and guiding translational research.Biological heterogeneity and target expression were further examined by Peslier et al. in a clinical study of patients with metastatic castration-resistant prostate cancer treated with 177 Lu-PSMA radioligand therapy. The authors identified clinical, biochemical, and PSMA PET-derived imaging factors associated with early treatment discontinuation and poor response, including markers of disease burden and reduced target expression. These findings emphasize that biological determinants of response play a critical role in radiopharmaceutical-based radiation treatments and reinforce the importance of biomarker-driven patient selection.Finally, Zając-Grabiec et al. reviewed non-cancer late effects following proton beam therapy in pediatric patients, focusing on neurocognitive, endocrine, cardiovascular, and brainstem toxicities. While proton therapy offers superior normal-tissue sparing compared with photon-based approaches, the review highlights that biological sensitivity of developing tissues remains a key determinant of long-term outcomes. This contribution underscores that precision radiation oncology must balance tumor control with age-dependent biological vulnerability when optimizing treatment strategies in pediatric populations.Together, these studies illustrate that precision radiation oncology extends well beyond technical optimization of dose delivery. Immune signaling pathways, tumor microenvironment biology, radiopharmaceutical target expression, and normal-tissue susceptibility all shape therapeutic response and toxicity. Integrating biological stratification, mechanistic insight, and biomarkerguided decision-making into radiation oncology practice will be essential for overcoming resistance, improving combination strategies, and advancing truly personalized radiation treatment.Together, the contributions in this Research Topic demonstrate that precision radiation oncology extends beyond technical optimization of dose delivery to encompass imaging, adaptive workflows, biological modulation, and clinical implementation. By integrating advanced planning and verification, real-time adaptation, molecular and immune insights, and biomarker-guided decision-making, these studies collectively advance more effective, resilient, and truly personalized radiation treatment strategies.

Authors

Institutions

Publication Details

Journal
Frontiers in Medicine
Published
2026-01-22
DOI
https://doi.org/10.3389/fmed.2026.1776567
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Editorial: Innovative approaches in precision radiation oncology

Abdul Kareem Parchur, P. Yadav
Frontiers in Medicine
Advanced Radiotherapy Techniques
article

Editorial: Innovative approaches in precision radiation oncology

Abdul Kareem Parchur, P. Yadav
article en

Abstract

Advancing spatially fractionated radiotherapy, Ma et al. introduced an optimization framework for determining vertex placement in lattice radiotherapy using closest packing combined with adaptive simulated annealing. Their method significantly increased the peak-to-valley dose contrast, with the optimized plans demonstrating a nearly six-fold improvement in peak-to-valley index compared with conventional packing approaches, highlighting a reproducible and automated strategy to enhance treatment precision for bulky tumors. Complementing this work on spatial dose modulation, Li et al. evaluated proton-based stereotactic centralized/core ablative radiation therapy (pSCART) in a treatment planning study of bulky tumors. By leveraging the physical dose advantages of protons, pSCART enabled higher prescription doses (24 Gy × 3 fractions) and improved high-dose central coverage while reducing dose spill at the tumor periphery and lowering mean doses to surrounding OARs compared with photon-based SCART techniques, supporting its potential for future clinical translation. Also, contributions focused on optimization of volumetric modulated arc therapy (VMAT) planning parameters to improve OAR protection without compromising target coverage. Guo et al. demonstrated that careful adjustment of physical parameters in a knowledge-based partial-arc VMAT RapidPlan model for left-sided breast cancer significantly reduced doses to the heart, lungs, and contralateral breast, emphasizing the importance of aligning model configuration with delivery geometry to mitigate low-dose exposure and secondary cancer risk. In a related dosimetric study, Huang et al. showed that incorporating orthogonal collimator angles (0°/90°) in dual-arc VMAT improved conformity, dose gradient, and OAR sparing across head-and-neck, thoracic, and pelvic sites, with all plans maintaining high delivery accuracy, demonstrating a simple yet effective planning refinement applicable in routine practice. Optimization of biological and clinical dose constraints was further explored by Hu et al., who investigated the use of the Monaco serial biological function for cardiac dose optimization in deep-inspiration breath-hold IMRT for leftsided breast cancer. Their analysis identified an optimal K-value range (2-4) that achieved balanced reduction in mean and maximum cardiac and coronary artery doses while preserving target coverage, providing evidence-based guidance for biologically informed planning parameter selection. Innovations in system-specific planning were also highlighted. Tang et al. developed a hippocampal-sparing whole-brain radiotherapy planning approach using the Halcyon platform with coplanar dual-arc VMAT and target substructure segmentation. Compared with conventional systems, this strategy achieved improved dose homogeneity, reduced hippocampal dose and normal tissue complication probability, and high gamma passing rates, demonstrating that advanced planning techniques can enhance neurocognitive preservation without increasing workflow complexity. Furthermore, clinical feasibility of advanced planning and delivery workflows was reinforced by Sun et al., who evaluated fan-beam CT-guided online adaptive replanning in definitive cervical cancer radiotherapy. Across 278 adaptive fractions, their approach consistently improved target coverage and OAR sparing with a mean gamma passing rate exceeding 99% and a clinically acceptable workflow duration of approximately 23 minutes, underscoring how optimized planning and delivery strategies can be successfully integrated into routine clinical practice. In the context of rare pediatric tumors, Zhang et al. reported a multimodal precision treatment strategy for MN1-altered astroblastoma, demonstrating how the tissue-sparing advantages of proton beam therapy can facilitate effective salvage Gamma Knife radiosurgery while maintaining durable local control and minimal toxicity.2. Imaging, Dosimetry, and Verification: Advanced imaging, quantitative dosimetry, and rigorous verification are foundational to precision radiation oncology, enabling accurate target definition, reliable dose delivery, and safe clinical implementation of increasingly complex treatment techniques. Six contributions in this Research Topic addressed these themes across clinical, technical, and preclinical domains, highlighting how imaging and verification strategies directly influence treatment accuracy, toxicity, and translational reliability.Several studies focused on dosimetric characterization and verification of complex delivery techniques. Wang et al. performed a comprehensive dosimetric and efficiency comparison between TomoDirect and TomoHelical radiotherapy for total skin irradiation. Their analysis demonstrated that TomoDirect plans using more than nine beams achieved target coverage, homogeneity, and organ-at-risk sparing comparable to TomoHelical delivery, while maintaining similar treatment times when appropriate auxiliary structure blocking was applied. These findings provide practical guidance for modality selection and protocol design in total skin irradiation, where large treatment volumes and delivery efficiency are critical. Quantitative assessment of dose delivery accuracy and verification was further advanced by Zhou et al., who developed a lightweight Swin-Transformer-based deep learning framework for patient-specific VMAT delivered-dose prediction. Their model achieved high structural similarity and gamma passing rates relative to ground truth dose distributions, while substantially reducing model complexity compared with existing transformer architectures. This work highlights the growing role of artificial intelligence in patient-specific quality assurance, offering a scalable and clinically viable alternative to labor-intensive measurement-based verification workflows. The role of imaging in refining dosimetric evaluation and treatment response assessment was addressed in multiple contributions. Qian et al. analyzed quantitative imaging features derived from 18 F-DOPA PET in glioblastoma patients treated with dose-escalated radiotherapy. Their results demonstrated that pretreatment imaging signatures and early post-treatment changes could stratify survival outcomes in MGMT-unmethylated tumors and identify patients most likely to benefit from dose escalation. This study underscores the potential of functional imaging biomarkers to inform both dosimetric decision-making and adaptive treatment strategies. Similarly, Borowiec et al. evaluated the clinical value of extended baseline cross-sectional imaging in locally advanced high-risk breast cancer. By incorporating CT or PET-CT into initial staging, the authors showed that disease stage and radiation treatment planning were altered in a substantial proportion of patients, enabling highly customized dose delivery to surgically inaccessible nodal regions. Their findings emphasize that imaging choice at baseline can directly impact dosimetric strategy and treatment individualization. Geometric sensitivity and setup-related dose variation were examined by Xiao et al., who conducted a propensity-matched cohort study comparing supine and prone positioning in postoperative cervical cancer radiotherapy. While target coverage remained comparable, positioning significantly influenced organ dose distributions, setup error profiles, and acute toxicity patterns. This work highlights how verification of geometric and positional factors is integral to optimizing both dosimetry and clinical safety in pelvic radiotherapy. Finally, Tavakkoli et al. addressed verification and biological confounding factors in the preclinical evaluation of ultra-high dose-rate (FLASH) radiotherapy. Using a murine total abdominal irradiation model, they demonstrated that anesthetic-dependent tissue oxygenation critically determined the presence or absence of FLASH sparing. Their findings underscore the importance of rigorous control and reporting of physiological variables when verifying dose-response relationships, particularly for emerging technologies poised for clinical translation.Collectively, these studies demonstrate that precision radiation oncology relies not only on sophisticated planning and delivery techniques, but also on robust imaging, dosimetric evaluation, and verification frameworks. By integrating quantitative imaging, advanced computational verification, and careful assessment of geometric and biological uncertainties, these contributions provide essential foundations for safe, accurate, and personalized radiotherapy.The transition from advanced treatment concepts to routine clinical practice represents a critical step in precision radiation oncology. Three contributions within this Research Topic focused on adaptive and online radiotherapy workflows, emphasizing real-time plan adaptation, clinical feasibility, and practical considerations for implementation in busy treatment environments.Anchoring this theme, the technical feasibility of optimized planning and delivery was supported by Sun et al., who demonstrated high-accuracy fan-beam CT-guided online adaptive replanning in definitive cervical cancer radiotherapy, achieving consistent target coverage and organ-at-risk sparing across 278 fractions within a clinically acceptable workflow time. Building on this foundation, Asher et al. examined broader aspects of clinical implementation, focusing on workflow translation and operational considerations associated with adaptive radiotherapy adoption. Their study addressed practical challenges such as staffing, training, and integration of adaptive processes within existing clinical infrastructures, highlighting that successful implementation depends not only on technical capability but also on multidisciplinary coordination and institutional readiness. Complementing these perspectives, Pang et al. explored clinical adaptation strategies aimed at tailoring treatment delivery to patient-specific and time-varying anatomical changes. Their work emphasized decision-making frameworks for when and how to adapt treatment plans, underscoring the importance of balancing dosimetric benefit with workflow efficiency and clinical resource utilization.Collectively, these studies demonstrate that adaptive radiotherapy has progressed beyond proofof-concept, with emerging evidence supporting its safe and effective deployment in clinical practice (Yan et al.). By addressing real-time adaptation, workflow feasibility, and implementation strategy, these contributions provide a roadmap for translating adaptive radiotherapy technologies into routine patient care and advancing the clinical impact of precision radiation oncology.A defining challenge in precision radiation oncology is understanding how identical physical dose prescriptions can produce markedly different biological and clinical outcomes across patients. Several contributions in this Research Topic addressed this challenge by examining immune signaling pathways, tumor-microenvironment interactions, and biological predictors of treatment response, highlighting the importance of integrating molecular biology into radiation treatment paradigms.Xiong et al. provided a comprehensive mini-review of the cGAS-STING signaling pathway as a central mediator linking radiation-induced DNA damage to innate and adaptive immune activation in breast cancer. The authors emphasized the dual and subtype-dependent roles of cGAS-STING signaling, demonstrating that acute pathway activation can enhance antitumor immunity and radiosensitization, whereas chronic or dysregulated activation may promote immunosuppression, regulatory T-cell expansion, and therapeutic resistance. By integrating molecular mechanisms with emerging translational and clinical considerations across luminal, HER2-positive, and triple-negative breast cancer subtypes, this work underscores the need for subtype-specific immune modulation strategies when designing radiation-immunotherapy combinations.Complementing immune-centric mechanisms, Keepers et al. investigated biological response modulation using mouse pancreatic tumor organoids as a translational preclinical platform. Their study demonstrated that combining low-dose chemotherapy with fractionated radiation produced significantly greater tumor growth inhibition than either modality alone. This enhanced effect was associated with increased DNA damage signaling, elevated reactive oxygen species production, and suppression of mesenchymal markers, supporting the concept that biologically informed combination strategies can amplify radiation efficacy while potentially reducing treatment-related toxicity. The use of tumor-derived organoids further highlights the value of advanced biological models for evaluating radiation-drug interactions and guiding translational research.Biological heterogeneity and target expression were further examined by Peslier et al. in a clinical study of patients with metastatic castration-resistant prostate cancer treated with 177 Lu-PSMA radioligand therapy. The authors identified clinical, biochemical, and PSMA PET-derived imaging factors associated with early treatment discontinuation and poor response, including markers of disease burden and reduced target expression. These findings emphasize that biological determinants of response play a critical role in radiopharmaceutical-based radiation treatments and reinforce the importance of biomarker-driven patient selection.Finally, Zając-Grabiec et al. reviewed non-cancer late effects following proton beam therapy in pediatric patients, focusing on neurocognitive, endocrine, cardiovascular, and brainstem toxicities. While proton therapy offers superior normal-tissue sparing compared with photon-based approaches, the review highlights that biological sensitivity of developing tissues remains a key determinant of long-term outcomes. This contribution underscores that precision radiation oncology must balance tumor control with age-dependent biological vulnerability when optimizing treatment strategies in pediatric populations.Together, these studies illustrate that precision radiation oncology extends well beyond technical optimization of dose delivery. Immune signaling pathways, tumor microenvironment biology, radiopharmaceutical target expression, and normal-tissue susceptibility all shape therapeutic response and toxicity. Integrating biological stratification, mechanistic insight, and biomarkerguided decision-making into radiation oncology practice will be essential for overcoming resistance, improving combination strategies, and advancing truly personalized radiation treatment.Together, the contributions in this Research Topic demonstrate that precision radiation oncology extends beyond technical optimization of dose delivery to encompass imaging, adaptive workflows, biological modulation, and clinical implementation. By integrating advanced planning and verification, real-time adaptation, molecular and immune insights, and biomarker-guided decision-making, these studies collectively advance more effective, resilient, and truly personalized radiation treatment strategies.

Frontiers in MedicineVol. 13
Northwestern University (US), University of Maryland, Baltimore (US)
Good health and well-being
Openalex Percentile: Top 81%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.