Algorithm for Reporting Free Hemoglobin in ECMO Patients: Need for a Multidisciplinary Approach

<b>Background:</b> Intravascular hemolysis is a common complication in patients undergoing extracorporeal membrane oxygenation (ECMO), with plasma free hemoglobin (pfHb) serving as a biomarker for detection. Without standardized protocols, laboratories face challenges in interpreting and reporting results. Hemolysis indices may enhance reporting accuracy. <b>Methods:</b> This retrospective observational study at University Hospital Center Zagreb included 61 lithium heparin plasma samples from ECMO patients. pfHb was measured using the Harboe method (fHb) and estimated from hemolysis indices on Abbott Alinity c analyzer (efHb). Total and conjugated bilirubin, hemolysis, icterus, and lipemia indices (HIL) were recorded. Method comparison used Passing-Bablok regression and Bland-Altman analysis. An algorithm for pfHb reporting accounting for HIL interferences was developed. <b>Results:</b> Significant differences were observed between methods, with Harboe yielding higher median fHb (261 mg/L) versus efHb (58 mg/L). Regression analysis showed constant negative bias of -91 mg/L (95% CI: -143 to -16) for efHb relative to fHb. Bland-Altman analysis demonstrated wide limits of agreement. Correlation between fHb and efHb was moderate (Spearman's rho = 0.618, <i>p</i> < 0.001). The delta between methods increased with higher bilirubin concentrations. An algorithm integrating HIL indices with the Harboe method was developed to guide result validation and reporting. <b>Conclusions:</b> Accurate hemolysis assessment in ECMO patients requires careful interpretation, appropriate method selection, and laboratory-clinician collaboration. The proposed algorithm improves the clinical utility of pfHb testing by accounting for analytical interferences and supporting informed decision-making.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-01-21
DOI
https://doi.org/10.3390/jcm15020867
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Algorithm for Reporting Free Hemoglobin in ECMO Patients: Need for a Multidisciplinary Approach

Ljiljana Zaninović, Dunja Rogić, Ana Lončar Vrančić, Dora Rebrek et al.
Journal of Clinical Medicine
Clinical Laboratory Practices and Quality Control
article

Algorithm for Reporting Free Hemoglobin in ECMO Patients: Need for a Multidisciplinary Approach

Ljiljana Zaninović, Dunja Rogić, Ana Lončar Vrančić, Dora Rebrek, Daniel Lovrić, Ivana Baršić Lapić
article en

Abstract

<b>Background:</b> Intravascular hemolysis is a common complication in patients undergoing extracorporeal membrane oxygenation (ECMO), with plasma free hemoglobin (pfHb) serving as a biomarker for detection. Without standardized protocols, laboratories face challenges in interpreting and reporting results. Hemolysis indices may enhance reporting accuracy. <b>Methods:</b> This retrospective observational study at University Hospital Center Zagreb included 61 lithium heparin plasma samples from ECMO patients. pfHb was measured using the Harboe method (fHb) and estimated from hemolysis indices on Abbott Alinity c analyzer (efHb). Total and conjugated bilirubin, hemolysis, icterus, and lipemia indices (HIL) were recorded. Method comparison used Passing-Bablok regression and Bland-Altman analysis. An algorithm for pfHb reporting accounting for HIL interferences was developed. <b>Results:</b> Significant differences were observed between methods, with Harboe yielding higher median fHb (261 mg/L) versus efHb (58 mg/L). Regression analysis showed constant negative bias of -91 mg/L (95% CI: -143 to -16) for efHb relative to fHb. Bland-Altman analysis demonstrated wide limits of agreement. Correlation between fHb and efHb was moderate (Spearman's rho = 0.618, <i>p</i> < 0.001). The delta between methods increased with higher bilirubin concentrations. An algorithm integrating HIL indices with the Harboe method was developed to guide result validation and reporting. <b>Conclusions:</b> Accurate hemolysis assessment in ECMO patients requires careful interpretation, appropriate method selection, and laboratory-clinician collaboration. The proposed algorithm improves the clinical utility of pfHb testing by accounting for analytical interferences and supporting informed decision-making.

Journal of Clinical MedicineVol. 15(2)
University Hospital Centre Zagreb (HR)
Peace, Justice and strong institutions
Openalex Percentile: Top 83%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.