Robust Lifetime Estimation from HPGe Radiation-Sensor Time Series Using Pairwise Ratios and MFV Statistics

High-purity germanium (HPGe) gamma-ray detectors are core instruments in nuclear physics and astrophysics experiments, where long-term stability and reliable extraction of decay parameters are essential. However, the standard exponential decay analyses of the detector time-series data are often affected by the strong correlations between the fitted parameters and the sensitivity to detector-related fluctuations and outliers. In this study, we present a robust analysis framework for HPGe detector decay data based on pairwise ratios and the Steiner's most frequent value (MFV) statistic. By forming point-to-point ratios of background-subtracted net counts, the dependence on the absolute detector response is eliminated, removing the amplitude-lifetime correlation that is inherent to conventional regression. The resulting pairwise lifetime estimates exhibit heavy-tailed behavior, which is efficiently summarized using the MFV, a robust estimator designed for such distributions. For the case study, a long and stable dataset from an HPGe detector was used. This data was gathered during a low-temperature nuclear physics experiment focused on observing the 216 keV gamma-ray line in <sup>97</sup>Ru. Using measurements spanning approximately 10 half-lives, we obtain a mean lifetime of τ=4.0959±0.0007stat±0.0110syst d, corresponding to a half-life of T1/2=2.8391±0.0005stat±0.0076syst d. These results demonstrate that the pairwise-MFV approach provides a robust and reproducible tool for analyzing long-duration HPGe detector data in nuclear physics and nuclear astrophysics experiments, particularly for precision decay measurements, detector-stability studies, and low-background monitoring.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-21
DOI
https://doi.org/10.3390/s26020706
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust Lifetime Estimation from HPGe Radiation-Sensor Time Series Using Pairwise Ratios and MFV Statistics

Victor Golovko
Sensors
Radioactive Decay and Measurement Techniques
article

Robust Lifetime Estimation from HPGe Radiation-Sensor Time Series Using Pairwise Ratios and MFV Statistics

Victor Golovko
article en

Abstract

High-purity germanium (HPGe) gamma-ray detectors are core instruments in nuclear physics and astrophysics experiments, where long-term stability and reliable extraction of decay parameters are essential. However, the standard exponential decay analyses of the detector time-series data are often affected by the strong correlations between the fitted parameters and the sensitivity to detector-related fluctuations and outliers. In this study, we present a robust analysis framework for HPGe detector decay data based on pairwise ratios and the Steiner's most frequent value (MFV) statistic. By forming point-to-point ratios of background-subtracted net counts, the dependence on the absolute detector response is eliminated, removing the amplitude-lifetime correlation that is inherent to conventional regression. The resulting pairwise lifetime estimates exhibit heavy-tailed behavior, which is efficiently summarized using the MFV, a robust estimator designed for such distributions. For the case study, a long and stable dataset from an HPGe detector was used. This data was gathered during a low-temperature nuclear physics experiment focused on observing the 216 keV gamma-ray line in <sup>97</sup>Ru. Using measurements spanning approximately 10 half-lives, we obtain a mean lifetime of τ=4.0959±0.0007stat±0.0110syst d, corresponding to a half-life of T1/2=2.8391±0.0005stat±0.0076syst d. These results demonstrate that the pairwise-MFV approach provides a robust and reproducible tool for analyzing long-duration HPGe detector data in nuclear physics and nuclear astrophysics experiments, particularly for precision decay measurements, detector-stability studies, and low-background monitoring.

SensorsVol. 26(2)
Canadian Nuclear Laboratories (CA)
Canadian Nuclear Laboratories
Openalex Percentile: Top 81%
Radioactive Decay and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.