Accurate modelling of intrabeam scattering and its impact on photoinjectors for free-electron lasers

Intrabeam scattering (IBS) is a fundamental effect that can limit the performance of high-brightness electron machines but has so far been neglected in standard modeling of RF photoinjectors. Recent measurements at SwissFEL show that the slice energy spread (SES) in the injector is significantly underestimated in standard beam dynamic simulations. In this paper, we employ a dedicated Monte Carlo simulation model that accurately predicts IBS-induced SES growth in the photoinjector of an X-ray free-electron laser. The simulations are benchmarked against SES measurements at the SwissFEL and are supported by a new analytical model. The results show that IBS-induced SES growth occurs throughout the injector, most prominently in the electron source, and must be included in performance assessments. We further demonstrate that while 5D brightness is largely conserved, the 6D brightness degrades with propagation, highlighting the need to account for IBS in accurate photoinjector design and optimization.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-21
DOI
https://doi.org/10.1038/s41598-026-36558-3
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate modelling of intrabeam scattering and its impact on photoinjectors for free-electron lasers

S. Reiche, Thomas G. Lucas, Eduard Prát, Paolo Craievich et al.
Scientific Reports
Particle Accelerators and Free-Electron Lasers
article

Accurate modelling of intrabeam scattering and its impact on photoinjectors for free-electron lasers

S. Reiche, Thomas G. Lucas, Eduard Prát, Paolo Craievich, Erion Gjonaj
article en

Abstract

Intrabeam scattering (IBS) is a fundamental effect that can limit the performance of high-brightness electron machines but has so far been neglected in standard modeling of RF photoinjectors. Recent measurements at SwissFEL show that the slice energy spread (SES) in the injector is significantly underestimated in standard beam dynamic simulations. In this paper, we employ a dedicated Monte Carlo simulation model that accurately predicts IBS-induced SES growth in the photoinjector of an X-ray free-electron laser. The simulations are benchmarked against SES measurements at the SwissFEL and are supported by a new analytical model. The results show that IBS-induced SES growth occurs throughout the injector, most prominently in the electron source, and must be included in performance assessments. We further demonstrate that while 5D brightness is largely conserved, the 6D brightness degrades with propagation, highlighting the need to account for IBS in accurate photoinjector design and optimization.

Scientific ReportsVol. 16(1)
Paul Scherrer Institute (CH), Technische Universität Darmstadt (DE)
Affordable and clean energy
Openalex Percentile: Top 81%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accurate modelling of intrabeam scattering and its impact on photoinjectors for free-electron lasers — S. Reiche, Thomas G. Lucas, et al. · Scientific Reports (2026) | TGRS Research Map | TGRS