Thermo-mechanical response of encased steel-tube prestressed concrete beams: influence of load ratio, cover thickness and partial prestressing ratio under fire

Purpose This study investigates the fire resistance of encased steel tube prestressed concrete (ESPC) beams, addressing the critical challenge of prestressed systems losing strength under elevated temperatures. Conventional prestressed beams are vulnerable to fire due to prestress loss, rapid thermal penetration and spalling. Limited research has explored how load ratio, tendon cover thickness and partial prestressing ratio (PPR) collectively influence thermo-mechanical performance. Design/methodology/approach A combined experimental and analytical program was conducted, including full-scale fire exposure tests and validated finite element simulations. The study systematically varied load ratios (η = 0.25–0.5), tendon cover thicknesses (45 mm and 70 mm) and PPR values (0.5–0.75). Key response parameters such as deflection, stiffness degradation, cracking patterns, torsional behavior and ultimate failure modes were examined up to 600°C. Findings Results revealed that a higher load ratio (η = 0.5) significantly enhanced fire resistance by sustaining internal force equilibrium and delaying failure. Thinner covers (45 mm) accelerated thermal ingress but mitigated explosive spalling, whereas thicker covers (70 mm) effectively protected tendons, extending beam stability. PPR exerted a strong influence, with higher ratios (0.75) accelerating cracking and reducing ductility, while optimized combinations of η, tendon cover and PPR improved residual strength and energy absorption. Balanced prestressing and confinement were shown to enhance torsional stiffness and ductility, yielding superior fire resilience. Originality/value This work provides the first integrated evaluation of ESPC beams under fire, establishing clear correlations between thermal degradation and mechanical response. By offering design-oriented recommendations on prestressing configuration, tendon cover and PPR optimization, the study advances structural fire engineering and guides the development of fire-safe prestressed systems.

Authors

Institutions

Publication Details

Journal
Journal of Structural Fire Engineering
Published
2026-01-21
DOI
https://doi.org/10.1108/jsfe-09-2025-0043
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermo-mechanical response of encased steel-tube prestressed concrete beams: influence of load ratio, cover thickness and partial prestressing ratio under fire

Badrinarayan Rath, Misra Hassen
Journal of Structural Fire Engineering
Fire effects on concrete materials
article

Thermo-mechanical response of encased steel-tube prestressed concrete beams: influence of load ratio, cover thickness and partial prestressing ratio under fire

Badrinarayan Rath, Misra Hassen
article en

Abstract

Purpose This study investigates the fire resistance of encased steel tube prestressed concrete (ESPC) beams, addressing the critical challenge of prestressed systems losing strength under elevated temperatures. Conventional prestressed beams are vulnerable to fire due to prestress loss, rapid thermal penetration and spalling. Limited research has explored how load ratio, tendon cover thickness and partial prestressing ratio (PPR) collectively influence thermo-mechanical performance. Design/methodology/approach A combined experimental and analytical program was conducted, including full-scale fire exposure tests and validated finite element simulations. The study systematically varied load ratios (η = 0.25–0.5), tendon cover thicknesses (45 mm and 70 mm) and PPR values (0.5–0.75). Key response parameters such as deflection, stiffness degradation, cracking patterns, torsional behavior and ultimate failure modes were examined up to 600°C. Findings Results revealed that a higher load ratio (η = 0.5) significantly enhanced fire resistance by sustaining internal force equilibrium and delaying failure. Thinner covers (45 mm) accelerated thermal ingress but mitigated explosive spalling, whereas thicker covers (70 mm) effectively protected tendons, extending beam stability. PPR exerted a strong influence, with higher ratios (0.75) accelerating cracking and reducing ductility, while optimized combinations of η, tendon cover and PPR improved residual strength and energy absorption. Balanced prestressing and confinement were shown to enhance torsional stiffness and ductility, yielding superior fire resilience. Originality/value This work provides the first integrated evaluation of ESPC beams under fire, establishing clear correlations between thermal degradation and mechanical response. By offering design-oriented recommendations on prestressing configuration, tendon cover and PPR optimization, the study advances structural fire engineering and guides the development of fire-safe prestressed systems.

Journal of Structural Fire Engineering
Wollega University (ET), Graphic Era University (IN)
Openalex Percentile: Top 82%
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.