Wear resistance of smooth TiO2 coating obtained by anodic oxidation and sol-gel dip-coating combination

This study investigates the wear behavior of crystalline TiO₂ coatings on Ti-6Al-4V substrates: a sol-gel only film (TSS; thickness ∼ 90 nm) and a combined anodic-oxidation and sol-gel system (TASS; thickness ∼ 600 nm). Wear tests employed reciprocating ball-on-flat apparatus with a conical diamond counterface (hemispherical tip radius 10 µm) to replicate prosthetic-valve leaflet motion under dry, unlubricated conditions at service-like or higher sliding speeds and contact pressures (∼10 000 MPa). Tests were run at loads of 39, 78, 117 and 156 mN for 1–4 min. Wear scars and debris were examined qualitatively, while wear volume, wear rate and wear factor were quantified with statistical analysis and uncertainty propagation. At the lowest loads (39 and 78 mN), both TSS and TASS outperformed the bare Ti-6Al-4V, exhibiting significantly lower wear volumes. At 117 mN, TSS exhibited the highest wear volumes—attributed to abrasive TiO₂ debris—whereas TASS remained comparable to the bare alloy; at 156 mN, TASS maintained lower wear than TSS and matched the substrate. Coatings that did not fail—i.e., did not expose the Ti-6Al-4V surface—showed wear factors of 2 × 10 − 4 to 3 × 10 − 4 m m 3 N − 1 m ⁻ ¹ , consistent with literature. Wear-rate maps, created separately for bare Ti-6Al-4V, TSS and TASS by fitting wear rate versus load and time, illustrate each system’s load-time response and reveal that TASS extends the low-wear regime relative to TSS. These maps offer a predictive framework for optimizing coating design in durable biomedical devices. • Smooth TiO 2 coatings of 100 and 600 nm thicknesses were obtained on Ti-6Al-4V. • Ball-on-flat tests were performed with loads ranging from 39 to 156 mN for 1–4 min. • The thickest coating showed the highest wear resistance. • The wear increased linearly over time but increased suddenly when the coating failed. • TiO 2 debris accelerated the wear after the coating failed.

Authors

Institutions

Publication Details

Journal
Next Materials
Published
2026-01-21
DOI
https://doi.org/10.1016/j.nxmate.2026.101609
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wear resistance of smooth TiO2 coating obtained by anodic oxidation and sol-gel dip-coating combination

Jonathan M. Schuster, Mario Roberto Rosenberger, Carlos E. Schvezov, María L. Vera
Next Materials
Bone Tissue Engineering Materials
article

Wear resistance of smooth TiO2 coating obtained by anodic oxidation and sol-gel dip-coating combination

Jonathan M. Schuster, Mario Roberto Rosenberger, Carlos E. Schvezov, María L. Vera
article en

Abstract

This study investigates the wear behavior of crystalline TiO₂ coatings on Ti-6Al-4V substrates: a sol-gel only film (TSS; thickness ∼ 90 nm) and a combined anodic-oxidation and sol-gel system (TASS; thickness ∼ 600 nm). Wear tests employed reciprocating ball-on-flat apparatus with a conical diamond counterface (hemispherical tip radius 10 µm) to replicate prosthetic-valve leaflet motion under dry, unlubricated conditions at service-like or higher sliding speeds and contact pressures (∼10 000 MPa). Tests were run at loads of 39, 78, 117 and 156 mN for 1–4 min. Wear scars and debris were examined qualitatively, while wear volume, wear rate and wear factor were quantified with statistical analysis and uncertainty propagation. At the lowest loads (39 and 78 mN), both TSS and TASS outperformed the bare Ti-6Al-4V, exhibiting significantly lower wear volumes. At 117 mN, TSS exhibited the highest wear volumes—attributed to abrasive TiO₂ debris—whereas TASS remained comparable to the bare alloy; at 156 mN, TASS maintained lower wear than TSS and matched the substrate. Coatings that did not fail—i.e., did not expose the Ti-6Al-4V surface—showed wear factors of 2 × 10 − 4 to 3 × 10 − 4 m m 3 N − 1 m ⁻ ¹ , consistent with literature. Wear-rate maps, created separately for bare Ti-6Al-4V, TSS and TASS by fitting wear rate versus load and time, illustrate each system’s load-time response and reveal that TASS extends the low-wear regime relative to TSS. These maps offer a predictive framework for optimizing coating design in durable biomedical devices. • Smooth TiO 2 coatings of 100 and 600 nm thicknesses were obtained on Ti-6Al-4V. • Ball-on-flat tests were performed with loads ranging from 39 to 156 mN for 1–4 min. • The thickest coating showed the highest wear resistance. • The wear increased linearly over time but increased suddenly when the coating failed. • TiO 2 debris accelerated the wear after the coating failed.

Next MaterialsVol. 11
National University of Misiones (AR), National University of General San Martín (AR), Comisión Nacional de Energía Atómica (AR)
Openalex Percentile: Top 82%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.