Deep learning software and revised 2D model to segment bone in micro-CT scans

Deep learning (DL) enables automated bone segmentation in micro-CT datasets but can struggle to generalize across developmental stages, anatomical regions, and imaging conditions. We present BP-2D-03, which is a revised 2D Bone-Pores segmentation model. It was fitted to a dataset comprising 20 micro-CT scans spanning five mammalian species and 142,960 image patches. To manage the substantially larger and more varied dataset, we developed a DL software interface with modules for training ("BONe DLFit"), prediction ("BONe DLPred"), and evaluation ("BONe IoU"). These tools resolve prior issues such as slice-level data leakage, high memory usage, and limited multi-GPU support. Model performance was evaluated through three analyses. First, 5-fold cross-validation with three seeds per fold evaluated baseline robustness and stability. The model showed generally high mean Intersection-over-Union (IoU) with minimal variation across seeds, but performance varied more across folds related to differences in scan composition. These findings show that the baseline model is stable overall but that predictivity can decline for atypical scans. Second, 30 benchmarking experiments tested how model architecture, encoder backbone, and patch size influence segmentation IoU and computational efficiency. U-Net and UNet++ architectures with simple convolutional backbones (e.g., ResNet-18) achieved the highest IoU values, approaching 0.97. Third, cross-platform experiments confirmed that results are consistent across hardware configurations, operating systems, and implementations (Avizo 3D and standalone). Together, these analyses demonstrate that the BONe DL software delivers robust baseline performance and reproducible results across platforms.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioinformatics
Published
2026-01-21
DOI
https://doi.org/10.3389/fbinf.2025.1677527
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep learning software and revised 2D model to segment bone in micro-CT scans

Layla Al‐Nakkash, Andrew H. Lee, Jeremy Chavez, Kalah Walden et al.
Frontiers in Bioinformatics
Medical Imaging and Analysis
article

Deep learning software and revised 2D model to segment bone in micro-CT scans

Layla Al‐Nakkash, Andrew H. Lee, Jeremy Chavez, Kalah Walden, Manan Damani, Brandon Vera Covarrubias, Jacob Baradarian, Ganesh Talluri, Michael Molgaard, Helena Hanna, Thomas L. Broderick, Beau Nielson, Julian M. Moore
article en

Abstract

Deep learning (DL) enables automated bone segmentation in micro-CT datasets but can struggle to generalize across developmental stages, anatomical regions, and imaging conditions. We present BP-2D-03, which is a revised 2D Bone-Pores segmentation model. It was fitted to a dataset comprising 20 micro-CT scans spanning five mammalian species and 142,960 image patches. To manage the substantially larger and more varied dataset, we developed a DL software interface with modules for training ("BONe DLFit"), prediction ("BONe DLPred"), and evaluation ("BONe IoU"). These tools resolve prior issues such as slice-level data leakage, high memory usage, and limited multi-GPU support. Model performance was evaluated through three analyses. First, 5-fold cross-validation with three seeds per fold evaluated baseline robustness and stability. The model showed generally high mean Intersection-over-Union (IoU) with minimal variation across seeds, but performance varied more across folds related to differences in scan composition. These findings show that the baseline model is stable overall but that predictivity can decline for atypical scans. Second, 30 benchmarking experiments tested how model architecture, encoder backbone, and patch size influence segmentation IoU and computational efficiency. U-Net and UNet++ architectures with simple convolutional backbones (e.g., ResNet-18) achieved the highest IoU values, approaching 0.97. Third, cross-platform experiments confirmed that results are consistent across hardware configurations, operating systems, and implementations (Avizo 3D and standalone). Together, these analyses demonstrate that the BONe DL software delivers robust baseline performance and reproducible results across platforms.

Frontiers in BioinformaticsVol. 5
Midwestern University (US), Blind and Sight Impaired Society (GB)
Midwestern University
Openalex Percentile: Top 82%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.