Shape memory alloy coil training toward guided electrode array insertion in cochlear implants

Abstract Current cochlear implant technology has limited capability to both safely insert the electrode array fully to the apex of the cochlea and laterally position the array precisely within the cochlea. The use of a programmable shape memory alloy guidewire has the potential to improve both electrode insertion depth and lateral placement control. The purpose of this study was to quantify the difference between trained and activated shapes of electrically actuated small-diameter Nitinol wires and thereby to refine a wire training methodology. Nitinol wires with 50–250 µm diameters were trained to form a coil shape, with training time varying from 30 s to 10 min. Measurements were taken at the training, activation, and relaxation stages of the wire. To obtain consistent coil shape, larger-diameter (150–250 µm) wires typically require 6 min of training time, while smaller-diameter (50–100 µm) wires require a longer training time, approximately 10 min. Graphical abstract

Authors

Institutions

Publication Details

Journal
MRS Advances
Published
2026-01-20
DOI
https://doi.org/10.1557/s43580-026-01533-7
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shape memory alloy coil training toward guided electrode array insertion in cochlear implants

D. R. DeVries, J. S. Olafsen, Y. S. Yoon, S. Loden et al.
MRS Advances
Hearing Loss and Rehabilitation
article

Shape memory alloy coil training toward guided electrode array insertion in cochlear implants

D. R. DeVries, J. S. Olafsen, Y. S. Yoon, S. Loden, L. J. Olafsen, M. L. Salter
article en

Abstract

Abstract Current cochlear implant technology has limited capability to both safely insert the electrode array fully to the apex of the cochlea and laterally position the array precisely within the cochlea. The use of a programmable shape memory alloy guidewire has the potential to improve both electrode insertion depth and lateral placement control. The purpose of this study was to quantify the difference between trained and activated shapes of electrically actuated small-diameter Nitinol wires and thereby to refine a wire training methodology. Nitinol wires with 50–250 µm diameters were trained to form a coil shape, with training time varying from 30 s to 10 min. Measurements were taken at the training, activation, and relaxation stages of the wire. To obtain consistent coil shape, larger-diameter (150–250 µm) wires typically require 6 min of training time, while smaller-diameter (50–100 µm) wires require a longer training time, approximately 10 min. Graphical abstract

MRS Advances
Baylor University (US)
Openalex Percentile: Top 82%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.