Design optimization using GATE Monte Carlo simulations for a sub-0.5 mm resolution PET scanner with 3-layer DOI detectors

<i>Objective.</i>For rodent brain PET imaging, spatial resolution is the most important factor for identifying small brain structures. Previously, we developed a submillimeter resolution PET scanner with 1 mm crystal pitch using 3-layer depth-of-interaction (DOI) detectors. However, the spatial resolution was over 0.5 mm due to a relatively large crystal pitch and an unoptimized crystal layer design. Here we use Geant4 Application Tomographic Emission (GATE) Monte Carlo simulations to design and optimize a sub-0.5 mm resolution PET scanner with 3-layer DOI detectors.<i>Methods.</i>The proposed PET scanner has 2 rings, each of which has 16 DOI detectors, resulting in a 23.4 mm axial coverage. Each DOI detector has 3-layer lutetium yttrium orthosilicate crystal arrays with a 0.8 mm crystal pitch. We employed GATE Monte Carlo simulations to optimize three crystal layer designs, A (4 + 4 + 7 mm), B (3 + 4 + 4 mm), and C (3 + 3 + 5 mm). Spatial resolution and imaging performance were evaluated with a point source and resolution phantom using analytical and iterative algorithms.<i>Main results.</i>Among the three designs, design C provided the most uniform spatial resolution up to the radial offset of 15 mm. The 0.45 mm diameter rod structures were resolved clearly with design C using the iterative algorithm. The GATE simulation results agreed with the experimental data in terms of radial resolution except at the radial offset of 15 mm.<i>Significance.</i>We optimized the crystal layer design of the mouse brain PET scanner with GATE simulations, thereby achieving sub-0.5 mm resolution in the resolution phantom study.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-01-20
DOI
https://doi.org/10.1088/1361-6560/ae3b02
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design optimization using GATE Monte Carlo simulations for a sub-0.5 mm resolution PET scanner with 3-layer DOI detectors

Han Gyu Kang, Hideaki Tashima, Taiga Yamaya, Makoto Higuchi
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
article

Design optimization using GATE Monte Carlo simulations for a sub-0.5 mm resolution PET scanner with 3-layer DOI detectors

Han Gyu Kang, Hideaki Tashima, Taiga Yamaya, Makoto Higuchi
article en

Abstract

<i>Objective.</i>For rodent brain PET imaging, spatial resolution is the most important factor for identifying small brain structures. Previously, we developed a submillimeter resolution PET scanner with 1 mm crystal pitch using 3-layer depth-of-interaction (DOI) detectors. However, the spatial resolution was over 0.5 mm due to a relatively large crystal pitch and an unoptimized crystal layer design. Here we use Geant4 Application Tomographic Emission (GATE) Monte Carlo simulations to design and optimize a sub-0.5 mm resolution PET scanner with 3-layer DOI detectors.<i>Methods.</i>The proposed PET scanner has 2 rings, each of which has 16 DOI detectors, resulting in a 23.4 mm axial coverage. Each DOI detector has 3-layer lutetium yttrium orthosilicate crystal arrays with a 0.8 mm crystal pitch. We employed GATE Monte Carlo simulations to optimize three crystal layer designs, A (4 + 4 + 7 mm), B (3 + 4 + 4 mm), and C (3 + 3 + 5 mm). Spatial resolution and imaging performance were evaluated with a point source and resolution phantom using analytical and iterative algorithms.<i>Main results.</i>Among the three designs, design C provided the most uniform spatial resolution up to the radial offset of 15 mm. The 0.45 mm diameter rod structures were resolved clearly with design C using the iterative algorithm. The GATE simulation results agreed with the experimental data in terms of radial resolution except at the radial offset of 15 mm.<i>Significance.</i>We optimized the crystal layer design of the mouse brain PET scanner with GATE simulations, thereby achieving sub-0.5 mm resolution in the resolution phantom study.

Physics in Medicine and BiologyVol. 71(3)
National Institutes for Quantum Science and Technology (JP)
Openalex Percentile: Top 83%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.