Experimental study of environmental factors' impact on surface leakage currents of high-voltage support insulators

<ns0:p>Ensuring the reliability of high-voltage insulation systems is critical for the safe and efficient operation of power equipment. Surface leakage currents, formed under the influence of atmospheric and anthropogenic factors, accelerate the aging of insulation materials, reduce their dielectric strength, and increase the risk of emergency failures. Particular attention is given to the combined impact of relative humidity, temperature fluctuations, surface contamination, and wind speed, which together create highly unfavorable conditions for the operation of insulation systems and necessitate the implementation of automated approaches to monitoring and managing their condition.The aim of this work is to experimentally determine the influence of key climatic and anthropogenic factors on the leakage currents of support insulators, to assess the relative contribution of these factors, and to construct generalized graphical dependencies. The results obtained can be used to predict the performance of insulation systems and to develop automated methods for optimizing the operating modes of power equipment.The research was conducted on IOS-35-1000 UHL insulators operated at substations in the central region of Ukraine.It was found that the dominant influencing factors are relative humidity (30%), negative temperature difference (25%), and surface contamination (20%). Absolute humidity, duration of moisture exposure, and wind speed have a secondary effect on leakage current, with wind partially reducing surface conductivity. The experimental graphical dependencies reflect the dynamics of conductive layer formation under various moistening conditions.Critical operating conditions for insulation systems arise when high humidity, negative temperature differences, and the presence of a hygroscopic contamination layer are combined. The results obtained can be used to predict the reliability of insulation structures and to improve automated insulation condition monitoring systems.</ns0:p>

Authors

Institutions

Publication Details

Journal
Energy and automation
Published
2025-11-02
DOI
https://doi.org/10.31548/energiya5(81).2025.064
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study of environmental factors' impact on surface leakage currents of high-voltage support insulators

V. M. Pavlenko, K. H. Petrova, A. I. Kotysh, O. Y. Volianyk
Energy and automation
High voltage insulation and dielectric phenomena
article

Experimental study of environmental factors' impact on surface leakage currents of high-voltage support insulators

V. M. Pavlenko, K. H. Petrova, A. I. Kotysh, O. Y. Volianyk
article en

Abstract

<ns0:p>Ensuring the reliability of high-voltage insulation systems is critical for the safe and efficient operation of power equipment. Surface leakage currents, formed under the influence of atmospheric and anthropogenic factors, accelerate the aging of insulation materials, reduce their dielectric strength, and increase the risk of emergency failures. Particular attention is given to the combined impact of relative humidity, temperature fluctuations, surface contamination, and wind speed, which together create highly unfavorable conditions for the operation of insulation systems and necessitate the implementation of automated approaches to monitoring and managing their condition.The aim of this work is to experimentally determine the influence of key climatic and anthropogenic factors on the leakage currents of support insulators, to assess the relative contribution of these factors, and to construct generalized graphical dependencies. The results obtained can be used to predict the performance of insulation systems and to develop automated methods for optimizing the operating modes of power equipment.The research was conducted on IOS-35-1000 UHL insulators operated at substations in the central region of Ukraine.It was found that the dominant influencing factors are relative humidity (30%), negative temperature difference (25%), and surface contamination (20%). Absolute humidity, duration of moisture exposure, and wind speed have a secondary effect on leakage current, with wind partially reducing surface conductivity. The experimental graphical dependencies reflect the dynamics of conductive layer formation under various moistening conditions.Critical operating conditions for insulation systems arise when high humidity, negative temperature differences, and the presence of a hygroscopic contamination layer are combined. The results obtained can be used to predict the reliability of insulation structures and to improve automated insulation condition monitoring systems.</ns0:p>

Energy and automation
National University of Life and Environmental Sciences of Ukraine (UA), Kyiv National University of Technologies and Design (UA), Central Ukrainian National Technical University (UA)
Affordable and clean energy
Openalex Percentile: Top 46%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.