Adaptive integral backstepping control and stability analysis of a three‐level neutral point clamped inverter for single‐stage grid‐tied photovoltaic systems

Abstract This paper presents an advanced control technique for a single‐stage grid‐tied photovoltaic (PV) system, including a three‐level neutral point clamped inverter with an LCL filter. The control objectives are threefold: (i) achieving power factor correction (PFC) by ensuring a sinusoidal grid current in phase with the grid voltage; (ii) transferring maximum PV power to the grid and tightly regulating the DC bus voltage; (iii) maintaining capacitor voltages balance to ensure proper power exchange. The control design entails several difficulties, namely: (i) the system's inherent nonlinearity and high dimensionality; (ii) the uncertainty in some system parameters; (iii) the numerous unmeasurable state variables and parameters. The considered control problem is dealt with by synthesizing a multi‐loop adaptive controller featuring three main cascaded loops. The fast inner loop utilizes an integral backstepping control alongside the formal Lyapunov technique for PFC achievement. The outer loop incorporates a filtered proportional‐integral (PI) regulator for DC bus voltage adjustment to its maximum power point reference. The auxiliary balancing loop implements a PI regulator for neutral‐point voltage stabilization. The control system is further enhanced with an adaptive observer for online estimation of network voltage and impedance parameters. The closed‐loop system stability is formally established through system averaging analysis. MATLAB/Simulink simulations demonstrate the performance of the suggested adaptive controller under varying operating conditions, and comparative studies confirm its supremacy over different other inner loop controllers.

Authors

Institutions

Publication Details

Journal
Asian Journal of Control
Published
2026-01-21
DOI
https://doi.org/10.1002/asjc.70063
Citations
1
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
25.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive integral backstepping control and stability analysis of a three‐level neutral point clamped inverter for single‐stage grid‐tied photovoltaic systems

Siham Chakiri, Youssef Mchaouar, Younes Abouelmahjoub, Oussama Khentaoui et al.
1 citations
Asian Journal of Control
Microgrid Control and Optimization
25.04
article

Adaptive integral backstepping control and stability analysis of a three‐level neutral point clamped inverter for single‐stage grid‐tied photovoltaic systems

Siham Chakiri, Youssef Mchaouar, Younes Abouelmahjoub, Oussama Khentaoui, Fouad Giri, Hassan Abouobaida
article en
1 citations

Abstract

Abstract This paper presents an advanced control technique for a single‐stage grid‐tied photovoltaic (PV) system, including a three‐level neutral point clamped inverter with an LCL filter. The control objectives are threefold: (i) achieving power factor correction (PFC) by ensuring a sinusoidal grid current in phase with the grid voltage; (ii) transferring maximum PV power to the grid and tightly regulating the DC bus voltage; (iii) maintaining capacitor voltages balance to ensure proper power exchange. The control design entails several difficulties, namely: (i) the system's inherent nonlinearity and high dimensionality; (ii) the uncertainty in some system parameters; (iii) the numerous unmeasurable state variables and parameters. The considered control problem is dealt with by synthesizing a multi‐loop adaptive controller featuring three main cascaded loops. The fast inner loop utilizes an integral backstepping control alongside the formal Lyapunov technique for PFC achievement. The outer loop incorporates a filtered proportional‐integral (PI) regulator for DC bus voltage adjustment to its maximum power point reference. The auxiliary balancing loop implements a PI regulator for neutral‐point voltage stabilization. The control system is further enhanced with an adaptive observer for online estimation of network voltage and impedance parameters. The closed‐loop system stability is formally established through system averaging analysis. MATLAB/Simulink simulations demonstrate the performance of the suggested adaptive controller under varying operating conditions, and comparative studies confirm its supremacy over different other inner loop controllers.

Asian Journal of Control
Chouaib Doukkali University (MA), Université de Caen Normandie (FR)
Affordable and clean energy
Openalex Percentile: Top 2%
Microgrid Control and Optimization
25.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.