Faster Diagnosis of Suspected Lower Respiratory Tract Infections: Single-Center Evidence from BIOFIRE FilmArray® Pneumonia Panel Results vs. Conventional Culture Method

<b>Background/Objectives</b>: Syndromic multiplex PCR assays such as BIOFIRE FilmArray<sup>®</sup> Pneumonia (PN) panel enable rapid and simultaneous detection of bacterial and viral pathogens in respiratory specimens, improving diagnostic accuracy and patient management in lower respiratory tract infections (LRTIs). <b>Methods</b>: In this retrospective observational study, PN panel results in 410 bronchoalveolar lavage (BAL) samples from hospitalized patients with suspected pneumonia were analyzed and compared with those obtained using the conventional culture (CC) method. <b>Results</b>: The PN panel showed an overall positivity rate of 54%, detecting bacteria in 39.0% of samples, viruses in 7.1%, and atypical bacteria in 2.2%. Using the conventional culture (CC) method, 33.9% of samples tested positive. Overall, 83 (20.2%) samples that were positive by the PN panel were negative by CC, whereas only 14 specimens (3.4%) were positive by CC and negative by PN panel. The most frequently detected pathogen by both the PN panel and CC was <i>Staphylococcus aureus</i> (n = 67, 16.34% for PN; n = 40, 9.76% for CC). Regarding diagnostic performance, the PN panel demonstrated a sensitivity of 89.02%, a specificity of 97.86%, and an overall accuracy of 97.63%. Lower sensitivity values were observed only for the <i>Enterobacter cloacae</i> complex (57.14%) and the <i>Klebsiella pneumoniae</i> group (75%). Specificity exceeded 92% for all bacterial targets. <b>Conclusions</b>: The PN panel confirms enhanced pathogen detection and a shortened time-to-result. It serves as a valuable adjunct for the timely diagnosis of LRTIs, supporting antimicrobial stewardship through more precise and appropriate antibiotic selection.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-01-21
DOI
https://doi.org/10.3390/diagnostics16020342
Primary Topic
Pneumonia and Respiratory Infections
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Faster Diagnosis of Suspected Lower Respiratory Tract Infections: Single-Center Evidence from BIOFIRE FilmArray® Pneumonia Panel Results vs. Conventional Culture Method

Alessia Pirrone, E Tomassini, Caterina Biassoni, Béatrice Silvia Orena et al.
Diagnostics
Pneumonia and Respiratory Infections
article

Faster Diagnosis of Suspected Lower Respiratory Tract Infections: Single-Center Evidence from BIOFIRE FilmArray® Pneumonia Panel Results vs. Conventional Culture Method

Alessia Pirrone, E Tomassini, Caterina Biassoni, Béatrice Silvia Orena, Lisa Cariani, Marco Tonelli, M. D’Accico, Antonio Teri, Daniela Girelli, Annapaola Callegaro, Filippo Girardi
article en

Abstract

<b>Background/Objectives</b>: Syndromic multiplex PCR assays such as BIOFIRE FilmArray<sup>®</sup> Pneumonia (PN) panel enable rapid and simultaneous detection of bacterial and viral pathogens in respiratory specimens, improving diagnostic accuracy and patient management in lower respiratory tract infections (LRTIs). <b>Methods</b>: In this retrospective observational study, PN panel results in 410 bronchoalveolar lavage (BAL) samples from hospitalized patients with suspected pneumonia were analyzed and compared with those obtained using the conventional culture (CC) method. <b>Results</b>: The PN panel showed an overall positivity rate of 54%, detecting bacteria in 39.0% of samples, viruses in 7.1%, and atypical bacteria in 2.2%. Using the conventional culture (CC) method, 33.9% of samples tested positive. Overall, 83 (20.2%) samples that were positive by the PN panel were negative by CC, whereas only 14 specimens (3.4%) were positive by CC and negative by PN panel. The most frequently detected pathogen by both the PN panel and CC was <i>Staphylococcus aureus</i> (n = 67, 16.34% for PN; n = 40, 9.76% for CC). Regarding diagnostic performance, the PN panel demonstrated a sensitivity of 89.02%, a specificity of 97.86%, and an overall accuracy of 97.63%. Lower sensitivity values were observed only for the <i>Enterobacter cloacae</i> complex (57.14%) and the <i>Klebsiella pneumoniae</i> group (75%). Specificity exceeded 92% for all bacterial targets. <b>Conclusions</b>: The PN panel confirms enhanced pathogen detection and a shortened time-to-result. It serves as a valuable adjunct for the timely diagnosis of LRTIs, supporting antimicrobial stewardship through more precise and appropriate antibiotic selection.

DiagnosticsVol. 16(2)
University of Milan (IT), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT)
Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico
Good health and well-being
Openalex Percentile: Top 82%
Pneumonia and Respiratory Infections
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.