pH-based control of NH4+ and Mn2+ oxidation sequence in low-oxygen groundwater filters

Iron (Fe<sup>2+</sup>), manganese (Mn<sup>2+</sup>), and ammonium (NH<sub>4</sub><sup>+</sup>) are the three most common contaminants in anaerobic groundwater and are typically removed in rapid sand filters in a series of simultaneous, uncontrolled, and interconnected redox reactions. In this study, we demonstrated separation of these oxidation processes, including reversing the order of NH<sub>4</sub><sup>+</sup>and Mn<sup>2+</sup>oxidation, allowing Mn<sup>2+</sup>to oxidize before NH<sub>4</sub><sup>+</sup>. To achieve this uncommon sequence, the filter was operated with low O<sub>2</sub> concentrations (∼0.02 mmol/L, ∼0.5 mg/L) and a high pH (∼8). Under these conditions, Mn<sup>2+</sup> oxidation is consuming all available O<sub>2</sub>, suppressing the occurrence of NH<sub>4</sub><sup>+</sup>oxidation. In the filter with low O<sub>2</sub> (0.08 mmol/L, ∼3 mg/L) and low pH (∼6.8), the opposite was observed, as Mn<sup>2+</sup> oxidation was delayed under these conditions, resulting in complete O<sub>2</sub> consumption by NH<sub>4</sub><sup>+</sup>-oxidizing bacteria. Reactive transport modelling and parameter estimation revealed that Mn<sup>2+</sup> oxidation is one order of magnitude faster in absence of NH<sub>4</sub><sup>+</sup> oxidation (1.4 × 10<sup>-2</sup> vs 2.5 × 10<sup>-3</sup> mmol/L), whereas NH<sub>4</sub><sup>+</sup> oxidation seemed to be accelerated by simultaneous Mn<sup>2+</sup> oxidation (6.8 × 10<sup>-3</sup> vs 2.9 × 10<sup>-2</sup> s<sup>-1</sup>). This interconnection between Mn<sup>2+</sup> and NH<sub>4</sub><sup>+</sup> oxidation was further emphasized by the observation of Mn<sup>2+</sup> release in the presence of NO<sub>2</sub><sup>-</sup>. In conclusion, this study has shown that a shift from conventional aerated groundwater treatment to sequential oxidation in separate filters offers (i) a more controllable system, (ii) the potential to optimize the rates of each oxidation process separately, which would ultimately result in higher flows and less backwashing.

Authors

Institutions

Publication Details

Journal
Water Research
Published
2026-01-21
DOI
https://doi.org/10.1016/j.watres.2026.125436
Primary Topic
Geochemistry and Elemental Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

pH-based control of NH4+ and Mn2+ oxidation sequence in low-oxygen groundwater filters

Doris van Halem, Michele Laureni, Emiel Kruisdijk, Simon Müller et al.
Water Research
Geochemistry and Elemental Analysis
article

pH-based control of NH4+ and Mn2+ oxidation sequence in low-oxygen groundwater filters

Doris van Halem, Michele Laureni, Emiel Kruisdijk, Simon Müller, Francesc Corbera-Rubio, Melanie Nijboer, Frank Schoonenberg
article en

Abstract

Iron (Fe<sup>2+</sup>), manganese (Mn<sup>2+</sup>), and ammonium (NH<sub>4</sub><sup>+</sup>) are the three most common contaminants in anaerobic groundwater and are typically removed in rapid sand filters in a series of simultaneous, uncontrolled, and interconnected redox reactions. In this study, we demonstrated separation of these oxidation processes, including reversing the order of NH<sub>4</sub><sup>+</sup>and Mn<sup>2+</sup>oxidation, allowing Mn<sup>2+</sup>to oxidize before NH<sub>4</sub><sup>+</sup>. To achieve this uncommon sequence, the filter was operated with low O<sub>2</sub> concentrations (∼0.02 mmol/L, ∼0.5 mg/L) and a high pH (∼8). Under these conditions, Mn<sup>2+</sup> oxidation is consuming all available O<sub>2</sub>, suppressing the occurrence of NH<sub>4</sub><sup>+</sup>oxidation. In the filter with low O<sub>2</sub> (0.08 mmol/L, ∼3 mg/L) and low pH (∼6.8), the opposite was observed, as Mn<sup>2+</sup> oxidation was delayed under these conditions, resulting in complete O<sub>2</sub> consumption by NH<sub>4</sub><sup>+</sup>-oxidizing bacteria. Reactive transport modelling and parameter estimation revealed that Mn<sup>2+</sup> oxidation is one order of magnitude faster in absence of NH<sub>4</sub><sup>+</sup> oxidation (1.4 × 10<sup>-2</sup> vs 2.5 × 10<sup>-3</sup> mmol/L), whereas NH<sub>4</sub><sup>+</sup> oxidation seemed to be accelerated by simultaneous Mn<sup>2+</sup> oxidation (6.8 × 10<sup>-3</sup> vs 2.9 × 10<sup>-2</sup> s<sup>-1</sup>). This interconnection between Mn<sup>2+</sup> and NH<sub>4</sub><sup>+</sup> oxidation was further emphasized by the observation of Mn<sup>2+</sup> release in the presence of NO<sub>2</sub><sup>-</sup>. In conclusion, this study has shown that a shift from conventional aerated groundwater treatment to sequential oxidation in separate filters offers (i) a more controllable system, (ii) the potential to optimize the rates of each oxidation process separately, which would ultimately result in higher flows and less backwashing.

Water ResearchVol. 293
Viaa Christian University of Applied Sciences (NL), Swiss Federal Institute of Aquatic Science and Technology (CH), Delft University of Technology (NL)
Clean water and sanitation
Openalex Percentile: Top 84%
Geochemistry and Elemental Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.