A Diagnostic Algorithm for Reconstructing the Direction of Gunshots Using OsiriX and Maya in Living Patients: A Forensic Radiology Approach

<b>Background/Objectives:</b> Gunshot wounds in living patients present significant challenges from both a clinical and a forensic perspective. Understanding the exact trajectory of a bullet is crucial not only for guiding treatment but also for providing reliable documentation in legal settings. This work introduces a practical diagnostic workflow that combines OsiriX (V. 14.1.1), a DICOM viewer with advanced 3D tools, with Autodesk Maya, a modeling platform used to recreate the external shooting scene. <b>Methods:</b> CT scans obtained with multidetector systems were analyzed in OsiriX using a structured, seven-step process that included multiplanar reconstructions, 3D renderings, and region-of-interest tracking. The reconstructed trajectories were then exported to Maya, where they were integrated into a virtual model of the shooting scene to correlate internal findings with the incident's external dynamics. <b>Results:</b> The workflow allowed precise identification of entry and exit points, reliable reconstruction of bullet paths, and effective 3D visualization. While OsiriX provided detailed information for clinical and radiological purposes, the use of Maya enabled simulation of the external scene, improving forensic interpretation and courtroom presentation. The procedure proved reproducible across cases and compatible with emergency timelines. <b>Conclusions:</b> The combined use of OsiriX and Maya offers a reproducible and informative method for analyzing gunshot wounds in living patients. This approach not only supports surgical and diagnostic decisions but also enhances the forensic value of radiological data by linking internal trajectories to external shooting dynamics. Its integration into trauma imaging protocols and forensic workflows could represent a significant step toward standardized ballistic documentation.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-01-21
DOI
https://doi.org/10.3390/diagnostics16020344
Primary Topic
Autopsy Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Diagnostic Algorithm for Reconstructing the Direction of Gunshots Using OsiriX and Maya in Living Patients: A Forensic Radiology Approach

Simona Pellerito, Francesca Licitra, Mauro Midiri, Angelo Montana et al.
Diagnostics
Autopsy Techniques and Outcomes
article

A Diagnostic Algorithm for Reconstructing the Direction of Gunshots Using OsiriX and Maya in Living Patients: A Forensic Radiology Approach

Simona Pellerito, Francesca Licitra, Mauro Midiri, Angelo Montana, Tommaso D’Anna, Giuseppe Lo Re, Antonina Argo, Ginevra Malta, Stefania Zerbo
article en

Abstract

<b>Background/Objectives:</b> Gunshot wounds in living patients present significant challenges from both a clinical and a forensic perspective. Understanding the exact trajectory of a bullet is crucial not only for guiding treatment but also for providing reliable documentation in legal settings. This work introduces a practical diagnostic workflow that combines OsiriX (V. 14.1.1), a DICOM viewer with advanced 3D tools, with Autodesk Maya, a modeling platform used to recreate the external shooting scene. <b>Methods:</b> CT scans obtained with multidetector systems were analyzed in OsiriX using a structured, seven-step process that included multiplanar reconstructions, 3D renderings, and region-of-interest tracking. The reconstructed trajectories were then exported to Maya, where they were integrated into a virtual model of the shooting scene to correlate internal findings with the incident's external dynamics. <b>Results:</b> The workflow allowed precise identification of entry and exit points, reliable reconstruction of bullet paths, and effective 3D visualization. While OsiriX provided detailed information for clinical and radiological purposes, the use of Maya enabled simulation of the external scene, improving forensic interpretation and courtroom presentation. The procedure proved reproducible across cases and compatible with emergency timelines. <b>Conclusions:</b> The combined use of OsiriX and Maya offers a reproducible and informative method for analyzing gunshot wounds in living patients. This approach not only supports surgical and diagnostic decisions but also enhances the forensic value of radiological data by linking internal trajectories to external shooting dynamics. Its integration into trauma imaging protocols and forensic workflows could represent a significant step toward standardized ballistic documentation.

DiagnosticsVol. 16(2)
University of Rome Tor Vergata (IT), Marche Polytechnic University (IT), Department of Health (ES), University of Palermo (IT)
Peace, Justice and strong institutions
Openalex Percentile: Top 84%
Autopsy Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.