Randomized Clinical Trial Assessing Patient-reported Outcomes with Bar–Locator versus Bar–Clip Attachments in Mandibular Two-implant Overdentures

This randomized clinical trial compared patient satisfaction and oral health-related quality of life (OHRQoL) in edentulous individuals rehabilitated with mandibular two-implant overdentures retained by bar-locator or bar-clip attachments.A total of 16 edentulous participants received two implants in the mandibular canine regions and were randomly assigned to receive overdentures with either bar-locator or bar-clip attachments. Patient satisfaction was assessed using a 100-mm visual analog scale (VAS), and OHRQoL was measured using the Oral Health Impact Profile (OHIP-14) after 3 months of functional use. Independent samples <i>t</i>-tests were applied with a significance level of <i>p</i> < 0.05.Comparisons between the two attachment groups were performed using the independent samples <i>t</i>-test, and statistical significance was set at <i>p</i> < 0.05. In addition to <i>p</i>-values, effect sizes (Cohen's d) were calculated to assess the magnitude and clinical relevance of intergroup differences.The bar-locator group reported significantly higher satisfaction regarding denture stability, retention, and masticatory efficiency, whereas the bar-clip group demonstrated greater overall comfort and lower psychological discomfort scores. No statistically significant differences were found in other domains of satisfaction or OHRQoL.Both attachment systems improved patient satisfaction and OHRQoL, with each demonstrating distinct advantages. The bar-locator system provided superior functional performance, while the bar-clip system enhanced comfort and psychosocial adaptation. Clinical selection should be based on patient priorities and anatomical conditions.

Authors

Institutions

Publication Details

Journal
European Journal of Dentistry
Published
2026-01-20
DOI
https://doi.org/10.1055/s-0045-1814464
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Randomized Clinical Trial Assessing Patient-reported Outcomes with Bar–Locator versus Bar–Clip Attachments in Mandibular Two-implant Overdentures

Heba Wageh Abozaed, Fahad Alkhtani, Hamod Alqahtani, Mohamed Shady et al.
European Journal of Dentistry
Dental Implant Techniques and Outcomes
article

Randomized Clinical Trial Assessing Patient-reported Outcomes with Bar–Locator versus Bar–Clip Attachments in Mandibular Two-implant Overdentures

Heba Wageh Abozaed, Fahad Alkhtani, Hamod Alqahtani, Mohamed Shady, Abdulrahman Almalki
article en

Abstract

This randomized clinical trial compared patient satisfaction and oral health-related quality of life (OHRQoL) in edentulous individuals rehabilitated with mandibular two-implant overdentures retained by bar-locator or bar-clip attachments.A total of 16 edentulous participants received two implants in the mandibular canine regions and were randomly assigned to receive overdentures with either bar-locator or bar-clip attachments. Patient satisfaction was assessed using a 100-mm visual analog scale (VAS), and OHRQoL was measured using the Oral Health Impact Profile (OHIP-14) after 3 months of functional use. Independent samples <i>t</i>-tests were applied with a significance level of <i>p</i> < 0.05.Comparisons between the two attachment groups were performed using the independent samples <i>t</i>-test, and statistical significance was set at <i>p</i> < 0.05. In addition to <i>p</i>-values, effect sizes (Cohen's d) were calculated to assess the magnitude and clinical relevance of intergroup differences.The bar-locator group reported significantly higher satisfaction regarding denture stability, retention, and masticatory efficiency, whereas the bar-clip group demonstrated greater overall comfort and lower psychological discomfort scores. No statistically significant differences were found in other domains of satisfaction or OHRQoL.Both attachment systems improved patient satisfaction and OHRQoL, with each demonstrating distinct advantages. The bar-locator system provided superior functional performance, while the bar-clip system enhanced comfort and psychosocial adaptation. Clinical selection should be based on patient priorities and anatomical conditions.

European Journal of Dentistry
Prince Sattam Bin Abdulaziz University (SA), Mansoura University (EG)
Openalex Percentile: Top 83%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.