Rapid optimization of focused ultrasound for complex targeting with phased array transducers and precomputed propagation operators

<i>Objective</i>. Low-intensity focused ultrasound has emerged as a versatile tool for various applications including noninvasive neuromodulation and blood-brain barrier (BBB) opening. To achieve precise individual targeting, phase aberration correction (PAC) is essential to compensate for the heterogeneities introduced by the skull. Traditional methods for PAC are restricted to single point-based targets, resulting in elongated, cigar-shaped focal beams that often fail to align with the geometry of the intended target. Additionally, these approaches demand lengthy simulation times, making the simultaneous sonication of multiple targets within a reasonable timeframe infeasible.<i>Approach</i>. This work introduces rapid optimization-based sonication of volumetric brain targets. By leveraging a pair of linear phased array transducers aligned orthogonally above the skull, the approach is capable of optimizing phase and amplitude parameters within seconds to focus acoustic pressure at multiple targets inside target volumes while limiting potential off-target activation.<i>Main results</i>. Three brain areas were targeted under different orthogonal transducer alignments, enforcing the desired intracranial peak pressure at a minimum of three target points in each region. Further results demonstrate the sensitivity of transducer displacements, particularly with translational and rotational misalignments. A ray tracing correction scheme was employed, restoring the peak pressure at the intended target region while keeping the increase in off-target pressure below 20%.<i>Significance</i>. Overall, these advancements hold promise for enhancing targeting in focused ultrasound-guided BBB opening and neuromodulatory applications, expanding the utility of ultrasound in clinical and experimental settings.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-01-20
DOI
https://doi.org/10.1088/1361-6560/ae3afe
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid optimization of focused ultrasound for complex targeting with phased array transducers and precomputed propagation operators

Alexander Paulus, Kasra Naftchi-Ardebili, Kim Butts Pauly, Maximilian Valentin Hasslberger et al.
Physics in Medicine and Biology
Ultrasound and Hyperthermia Applications
article

Rapid optimization of focused ultrasound for complex targeting with phased array transducers and precomputed propagation operators

Alexander Paulus, Kasra Naftchi-Ardebili, Kim Butts Pauly, Maximilian Valentin Hasslberger, Mathew George Abraham
article en

Abstract

<i>Objective</i>. Low-intensity focused ultrasound has emerged as a versatile tool for various applications including noninvasive neuromodulation and blood-brain barrier (BBB) opening. To achieve precise individual targeting, phase aberration correction (PAC) is essential to compensate for the heterogeneities introduced by the skull. Traditional methods for PAC are restricted to single point-based targets, resulting in elongated, cigar-shaped focal beams that often fail to align with the geometry of the intended target. Additionally, these approaches demand lengthy simulation times, making the simultaneous sonication of multiple targets within a reasonable timeframe infeasible.<i>Approach</i>. This work introduces rapid optimization-based sonication of volumetric brain targets. By leveraging a pair of linear phased array transducers aligned orthogonally above the skull, the approach is capable of optimizing phase and amplitude parameters within seconds to focus acoustic pressure at multiple targets inside target volumes while limiting potential off-target activation.<i>Main results</i>. Three brain areas were targeted under different orthogonal transducer alignments, enforcing the desired intracranial peak pressure at a minimum of three target points in each region. Further results demonstrate the sensitivity of transducer displacements, particularly with translational and rotational misalignments. A ray tracing correction scheme was employed, restoring the peak pressure at the intended target region while keeping the increase in off-target pressure below 20%.<i>Significance</i>. Overall, these advancements hold promise for enhancing targeting in focused ultrasound-guided BBB opening and neuromodulatory applications, expanding the utility of ultrasound in clinical and experimental settings.

Physics in Medicine and BiologyVol. 71(3)
Austin College (US), Technical University of Munich (DE), The University of Texas at Austin (US), Stanford University (US)
Openalex Percentile: Top 82%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.