A double-crystal bent Laue parallel-beam compressor

We demonstrate the ability to manipulate a synchrotron X-ray beam's size, maintaining a nearly parallel beam, by `compressing' it horizontally using a pair of cylindrically bent Laue crystals. This compressed beam creates a desirable aspect ratio for computed tomography (CT) of small samples. In contrast to collimation of the beam, this compressor `funnels' a large horizontal section of the beam's flux into a smaller imaging area, raising intensity and allowing users to work in the gap between bend-magnet (BM) and insertion-device beamline intensities. We demonstrate here the proof-of-principle of this optical system with CT of multiple small samples. This system can increase the capability of CT at synchrotron facilities by allowing more flexibility in the intensity of BM beamlines. It also produces a spectral beam which will be further explored in future papers.

Authors

Institutions

Publication Details

Journal
Journal of Synchrotron Radiation
Published
2025-11-14
DOI
https://doi.org/10.1107/s1600577525009609
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A double-crystal bent Laue parallel-beam compressor

Glendon Rhoades, L. Dean Chapman
Journal of Synchrotron Radiation
Advanced X-ray Imaging Techniques
article

A double-crystal bent Laue parallel-beam compressor

Glendon Rhoades, L. Dean Chapman
article en

Abstract

We demonstrate the ability to manipulate a synchrotron X-ray beam's size, maintaining a nearly parallel beam, by `compressing' it horizontally using a pair of cylindrically bent Laue crystals. This compressed beam creates a desirable aspect ratio for computed tomography (CT) of small samples. In contrast to collimation of the beam, this compressor `funnels' a large horizontal section of the beam's flux into a smaller imaging area, raising intensity and allowing users to work in the gap between bend-magnet (BM) and insertion-device beamline intensities. We demonstrate here the proof-of-principle of this optical system with CT of multiple small samples. This system can increase the capability of CT at synchrotron facilities by allowing more flexibility in the intensity of BM beamlines. It also produces a spectral beam which will be further explored in future papers.

Journal of Synchrotron RadiationVol. 33(2)
University of Saskatchewan (CA)
Openalex Percentile: Top 25%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.