Factors Influencing Soil Corrosivity and Its Impact on Solar Photovoltaic Projects

Soil corrosion is a critical durability and cost factor for metallic foundations in photovoltaic (PV) power plants, yet it is still addressed with fragmented criteria compared with atmospheric corrosion. This paper reviews the main soil corrosivity drivers relevant to PV installations—moisture and aeration dynamics, electrical resistivity, pH and buffer capacity, dissolved ions (notably chlorides and sulfates), microbiological activity, hydro-climatic variability and geological heterogeneity—highlighting their coupled and non-linear effects, such as differential aeration, macrocell formation and corrosion localization. Building on this mechanistic basis, an engineering-oriented methodological roadmap is proposed to translate soil characterization into durability decisions. The approach combines soil corrosivity classification according to DIN 50929-3 and DVGW GW 9, tiered estimation of hot-dip galvanized coating consumption using AASHTO screening, resistivity–pH correlations and ionic penalty factors, and verification against conservative NBS envelopes. When coating life is insufficient, a traceable steel thickness allowance based on DIN bare-steel corrosion rates is introduced to meet the target service life. The framework provides a practical and auditable basis for durability design and risk control of PV foundations in heterogeneous soils. The proposed framework shows that, for soils exceeding AASHTO mild criteria, zinc corrosion rates may increase by a factor of 1.3–1.7 when chloride and sulfate penalties are considered, potentially reducing coating service life by more than 40%. The methodology proposed enables designers to estimate the penalty factors for sulfates (fpSO42−) and chlorides (fpCl−) in each specific project, calculating the appropriate values of KSO42− and KCl− using electrochemical techniques—ER/LPR and EIS—to estimate the effect of the soluble salts content in the ZnCorr Rate, not properly catch by the proxy indicator VcorrER, pH when sulfate and chloride content are over AAHSTO limits for mildly corrosive soils.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-01-21
DOI
https://doi.org/10.3390/app16021095
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factors Influencing Soil Corrosivity and Its Impact on Solar Photovoltaic Projects

Juan José del Campo Gorostidi, Iván Jares Salguero, Guillermo Laine Cuervo, Efrén García Ordiales
Applied Sciences
Corrosion Behavior and Inhibition
article

Factors Influencing Soil Corrosivity and Its Impact on Solar Photovoltaic Projects

Juan José del Campo Gorostidi, Iván Jares Salguero, Guillermo Laine Cuervo, Efrén García Ordiales
article en

Abstract

Soil corrosion is a critical durability and cost factor for metallic foundations in photovoltaic (PV) power plants, yet it is still addressed with fragmented criteria compared with atmospheric corrosion. This paper reviews the main soil corrosivity drivers relevant to PV installations—moisture and aeration dynamics, electrical resistivity, pH and buffer capacity, dissolved ions (notably chlorides and sulfates), microbiological activity, hydro-climatic variability and geological heterogeneity—highlighting their coupled and non-linear effects, such as differential aeration, macrocell formation and corrosion localization. Building on this mechanistic basis, an engineering-oriented methodological roadmap is proposed to translate soil characterization into durability decisions. The approach combines soil corrosivity classification according to DIN 50929-3 and DVGW GW 9, tiered estimation of hot-dip galvanized coating consumption using AASHTO screening, resistivity–pH correlations and ionic penalty factors, and verification against conservative NBS envelopes. When coating life is insufficient, a traceable steel thickness allowance based on DIN bare-steel corrosion rates is introduced to meet the target service life. The framework provides a practical and auditable basis for durability design and risk control of PV foundations in heterogeneous soils. The proposed framework shows that, for soils exceeding AASHTO mild criteria, zinc corrosion rates may increase by a factor of 1.3–1.7 when chloride and sulfate penalties are considered, potentially reducing coating service life by more than 40%. The methodology proposed enables designers to estimate the penalty factors for sulfates (fpSO42−) and chlorides (fpCl−) in each specific project, calculating the appropriate values of KSO42− and KCl− using electrochemical techniques—ER/LPR and EIS—to estimate the effect of the soluble salts content in the ZnCorr Rate, not properly catch by the proxy indicator VcorrER, pH when sulfate and chloride content are over AAHSTO limits for mildly corrosive soils.

Applied SciencesVol. 16(2)
Universidad de Oviedo (ES), Fundación Centro Tecnológico de la Información y la Comunicación (ES)
Openalex Percentile: Top 82%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.