Integrated assessment of the quality of microprocessor-based relay protection

<ns0:p>The article discusses the problems of assessing the effectiveness of microprocessor-based relay protection of power system facilities. The relevance of the study is due to the importance of relay protection devices in ensuring timely detection and elimination of emergency modes, preventing equipment damage, and maintaining the stability of the power system. Traditional approaches to assessing performance quality boil down to taking into account equipment and operational losses or are limited to the percentage of correct relay actions, which does not always allow for an accurate assessment of system efficiency.The purpose of the study is to develop an integrated criterion for evaluating the effectiveness of microprocessor-based relay protection, which takes into account functional and metrological losses caused by measurement errors, response delays, and other features of the implementation of protection algorithms.To analyze losses, it is proposed to classify them into groups: functional-metrological, related to the adjustment of settings and the properties of selectivity and sensitivity; indirect hardware, arising from component failures and personnel errors; independent of settings, including damage to equipment and infrastructure.For quantitative assessment of effectiveness, an integral indicatoris proposed, which takes into account all elements of the relay protection channel and allows assessing the probabilistic characteristics of losses and the potential effect of protection. To assess reliability, a normalized failure rateis used, which includes relay failures, incorrect protection actions, and personnel errors.An integrated approach allows for a comprehensive assessment of the efficiency, technical excellence, and economic feasibility of using microprocessor relay protection devices, predicting their behavior in emergency situations, optimizing settings, and increasing the adaptability and reliability of the system in real operating conditions. The use of the probabilistic-statistical method ensures objectivity of assessment and allows making informed decisions on the modernization and optimization of relay protection systems for power facilities.</ns0:p>

Authors

Publication Details

Journal
Energy and automation
Published
2025-12-31
DOI
https://doi.org/10.31548/energiya6(82).2025.052
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated assessment of the quality of microprocessor-based relay protection

M. Potapenko, V. Sharshon, V. Ramsh
Energy and automation
Electric Power Systems and Control
article

Integrated assessment of the quality of microprocessor-based relay protection

M. Potapenko, V. Sharshon, V. Ramsh
article en

Abstract

<ns0:p>The article discusses the problems of assessing the effectiveness of microprocessor-based relay protection of power system facilities. The relevance of the study is due to the importance of relay protection devices in ensuring timely detection and elimination of emergency modes, preventing equipment damage, and maintaining the stability of the power system. Traditional approaches to assessing performance quality boil down to taking into account equipment and operational losses or are limited to the percentage of correct relay actions, which does not always allow for an accurate assessment of system efficiency.The purpose of the study is to develop an integrated criterion for evaluating the effectiveness of microprocessor-based relay protection, which takes into account functional and metrological losses caused by measurement errors, response delays, and other features of the implementation of protection algorithms.To analyze losses, it is proposed to classify them into groups: functional-metrological, related to the adjustment of settings and the properties of selectivity and sensitivity; indirect hardware, arising from component failures and personnel errors; independent of settings, including damage to equipment and infrastructure.For quantitative assessment of effectiveness, an integral indicatoris proposed, which takes into account all elements of the relay protection channel and allows assessing the probabilistic characteristics of losses and the potential effect of protection. To assess reliability, a normalized failure rateis used, which includes relay failures, incorrect protection actions, and personnel errors.An integrated approach allows for a comprehensive assessment of the efficiency, technical excellence, and economic feasibility of using microprocessor relay protection devices, predicting their behavior in emergency situations, optimizing settings, and increasing the adaptability and reliability of the system in real operating conditions. The use of the probabilistic-statistical method ensures objectivity of assessment and allows making informed decisions on the modernization and optimization of relay protection systems for power facilities.</ns0:p>

Energy and automation
Industry, innovation and infrastructure
Openalex Percentile: Top 38%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Integrated assessment of the quality of microprocessor-based relay protection — M. Potapenko, V. Sharshon, et al. · Energy and automation (2025) | TGRS Research Map | TGRS