Evaluating the Resilience of Ventilation Strategies in Low-Energy Irish Schools

In the face of increasing global temperatures, this study aims to explore ventilation strategies that could provide passive cooling to mitigate overheating in studied low-energy school buildings, in particular those that use ventilative cooling. This study utilises building modelling calibrated with field data to tackle the challenge of maintaining indoor thermal comfort and cognitive performance levels during increasingly warm seasons. The calibrated building model is used to evaluate the vulnerability of classrooms, identifying and addressing risks based on standardised overheating and resilience criteria. Two primary school classrooms were simulated in three main cities across Ireland to assess the possibility of natural ventilative cooling for maintaining indoor thermal conditions without sacrificing energy efficiency. The study highlights the critical need to enhance natural ventilation strategies to protect against projected future overheating, with peak indoor temperatures reaching 29 °C to 31 °C during May, June, and September. Implementing a maximum natural ventilation strategy during occupied times, with a 9.6% opening-to-floor area ratio, can reduce peak indoor temperatures by up to 2.5 °C. Findings show Irish classrooms in low-energy buildings equipped with hybrid ventilative cooling can act as potential climate shelters during July and August under extreme weather conditions, underlining their capacity to provide a comfortable environment for vulnerable people during heatwaves and reduce overheating risk by 42–48% compared to natural ventilation. Additionally, projections show that cognitive performance loss in students may rise to 23% by 2071 due to raised indoor temperatures; however, this can be reduced to below 10% in 2021 and 2041 with maximum natural ventilation. The novelty of this work lies in its systematic evaluation of ventilative cooling resilience under future climate scenarios across multiple Irish city contexts, providing a robust evidence base for designing climate-resilient, energy-efficient learning environments.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-01-21
DOI
https://doi.org/10.3390/buildings16020452
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Resilience of Ventilation Strategies in Low-Energy Irish Schools

Adam O’Donovan, Paul D. O’Sullivan, Elahe Tavakoli
Buildings
Building Energy and Comfort Optimization
article

Evaluating the Resilience of Ventilation Strategies in Low-Energy Irish Schools

Adam O’Donovan, Paul D. O’Sullivan, Elahe Tavakoli
article en

Abstract

In the face of increasing global temperatures, this study aims to explore ventilation strategies that could provide passive cooling to mitigate overheating in studied low-energy school buildings, in particular those that use ventilative cooling. This study utilises building modelling calibrated with field data to tackle the challenge of maintaining indoor thermal comfort and cognitive performance levels during increasingly warm seasons. The calibrated building model is used to evaluate the vulnerability of classrooms, identifying and addressing risks based on standardised overheating and resilience criteria. Two primary school classrooms were simulated in three main cities across Ireland to assess the possibility of natural ventilative cooling for maintaining indoor thermal conditions without sacrificing energy efficiency. The study highlights the critical need to enhance natural ventilation strategies to protect against projected future overheating, with peak indoor temperatures reaching 29 °C to 31 °C during May, June, and September. Implementing a maximum natural ventilation strategy during occupied times, with a 9.6% opening-to-floor area ratio, can reduce peak indoor temperatures by up to 2.5 °C. Findings show Irish classrooms in low-energy buildings equipped with hybrid ventilative cooling can act as potential climate shelters during July and August under extreme weather conditions, underlining their capacity to provide a comfortable environment for vulnerable people during heatwaves and reduce overheating risk by 42–48% compared to natural ventilation. Additionally, projections show that cognitive performance loss in students may rise to 23% by 2071 due to raised indoor temperatures; however, this can be reduced to below 10% in 2021 and 2041 with maximum natural ventilation. The novelty of this work lies in its systematic evaluation of ventilative cooling resilience under future climate scenarios across multiple Irish city contexts, providing a robust evidence base for designing climate-resilient, energy-efficient learning environments.

BuildingsVol. 16(2)
Science Foundation Ireland (IE), Munster Technological University (IE)
Sustainable Energy Authority of Ireland
Climate action
Openalex Percentile: Top 83%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.