Optimization of Cryogenic Gas Separation Systems Based on Exergetic Analysis—The Claude–Heylandt Cycle for Oxygen Separation

In cryogenic air liquefaction systems, a major share of the mechanical energy consumption is associated with exergy destruction caused by heat transfer in recuperative heat exchangers. This study investigated the exergetic optimization of cryogenic gas separation systems by focusing on the Claude-Heylandt cycle as an advanced structural modification of the classical Linde-Hampson scheme. An exergy-based analysis demonstrates that minimizing mechanical energy consumption requires a progressive reduction in the temperature difference between the hot forward stream and the cold returning stream toward the cold end of the heat exchanger. This condition was achieved by extracting a fraction of the high-pressure stream and expanding it in a parallel expander, thereby creating a controlled imbalance in the heat capacities between the two streams. The proposed configuration reduces the share of exergy destruction associated with heat transfer in the recuperative heat exchanger from 14% to 3.5%, leading to a fourfold increase in the exergetic efficiency, together with a 3.6-fold increase in the liquefied air fraction compared with the Linde-Hampson cycle operating under identical conditions. The effects of key decision parameters, including the compression pressure, imposed temperature differences, and expander inlet temperature, were systematically analyzed. The study was further extended by integrating an air separation column into the Claude-Heylandt cycle and optimizing its configuration based on entropy generation minimization. The optimal liquid-air feeding height and threshold number of rectification trays were identified, beyond which further structural complexity yielded no thermodynamic benefit. The results highlight the effectiveness of exergy-based optimization as a unified design criterion for both cryogenic liquefaction and separation processes.

Authors

Institutions

Publication Details

Journal
Entropy
Published
2026-01-21
DOI
https://doi.org/10.3390/e28010125
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Cryogenic Gas Separation Systems Based on Exergetic Analysis—The Claude–Heylandt Cycle for Oxygen Separation

Alexandru Dobrovicescu, Lavinia Grosu, Alexandru Șerban, Adalia Andreea Percembli et al.
Entropy
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Optimization of Cryogenic Gas Separation Systems Based on Exergetic Analysis—The Claude–Heylandt Cycle for Oxygen Separation

Alexandru Dobrovicescu, Lavinia Grosu, Alexandru Șerban, Adalia Andreea Percembli, Dănuț-Cristian Urduza
article en

Abstract

In cryogenic air liquefaction systems, a major share of the mechanical energy consumption is associated with exergy destruction caused by heat transfer in recuperative heat exchangers. This study investigated the exergetic optimization of cryogenic gas separation systems by focusing on the Claude-Heylandt cycle as an advanced structural modification of the classical Linde-Hampson scheme. An exergy-based analysis demonstrates that minimizing mechanical energy consumption requires a progressive reduction in the temperature difference between the hot forward stream and the cold returning stream toward the cold end of the heat exchanger. This condition was achieved by extracting a fraction of the high-pressure stream and expanding it in a parallel expander, thereby creating a controlled imbalance in the heat capacities between the two streams. The proposed configuration reduces the share of exergy destruction associated with heat transfer in the recuperative heat exchanger from 14% to 3.5%, leading to a fourfold increase in the exergetic efficiency, together with a 3.6-fold increase in the liquefied air fraction compared with the Linde-Hampson cycle operating under identical conditions. The effects of key decision parameters, including the compression pressure, imposed temperature differences, and expander inlet temperature, were systematically analyzed. The study was further extended by integrating an air separation column into the Claude-Heylandt cycle and optimizing its configuration based on entropy generation minimization. The optimal liquid-air feeding height and threshold number of rectification trays were identified, beyond which further structural complexity yielded no thermodynamic benefit. The results highlight the effectiveness of exergy-based optimization as a unified design criterion for both cryogenic liquefaction and separation processes.

EntropyVol. 28(1)
Laboratoire Pluridisciplinaire de Recherche en Ingénierie des Systèmes, Mécanique et Energétique (FR), Universitatea Națională de Știință și Tehnologie Politehnica București (RO)
Affordable and clean energy
Openalex Percentile: Top 82%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.