A system for invitro inhaled/exhaled aerosol testing of personal protective equipment

Social distancing at six feet (about two meters), frequent hand hygiene, and using personal protective equipment (PPE) such as masks and shields are common practices to reduce the transmission of airborne viruses. An in-vitro system for testing and comparing a selection of PPE to prevent aerosol escape and aerosol intrusion at three distances and three angles is described. In the system tested, at six feet, face masks or shields provided markedly decreased aerosol transmission in a room with limited ventilation. At two feet, with a type of protection wearing manikin emitting aerosols of normal saline and a non-barrier receiver, the aerosol transmission increased with the use of a KN95 (+ 20%), a washable cloth mask (+ 25%), a disposable shield (+ 7%), a 3D printed shield (+ 3%), and a shop shield (+ 15%) compared to the case with no PPE used on either. Changing the angle at which the two manikins are facing each other affected aerosol transmission; compared to the manikins wearing an N95 mask and facing each other, an angle of 45° and 90° increased transmission by 43% and 52%, respectively. With both the generator and receiver wearing a disposable medical mask, aerosols detected at all distances were significantly attenuated. In the system tested, masks generally provided superior aerosol transmission reduction when compared to face shields. These resultsare not intended to guide PPE selection but may serve as a framework for future research and advanced testing methodology. It is reassuring to confirm however that the distance between the aerosol transmitter and receiver significantly reduced aerosol exposure and that a simple surgical mask worn by both transmitter and receiver markedly reduced transmission to near background levels. The manikin represents a scaled-down model; therefore, absolute flow fields differ from adult physiology. The findings should be interpreted in relative rather than absolute terms.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-21
DOI
https://doi.org/10.1038/s41598-026-35248-4
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A system for invitro inhaled/exhaled aerosol testing of personal protective equipment

Andrew K. Poznikoff, Alberto Baldelli, Robert Purdy
Scientific Reports
Infection Control and Ventilation
article

A system for invitro inhaled/exhaled aerosol testing of personal protective equipment

Andrew K. Poznikoff, Alberto Baldelli, Robert Purdy
article en

Abstract

Social distancing at six feet (about two meters), frequent hand hygiene, and using personal protective equipment (PPE) such as masks and shields are common practices to reduce the transmission of airborne viruses. An in-vitro system for testing and comparing a selection of PPE to prevent aerosol escape and aerosol intrusion at three distances and three angles is described. In the system tested, at six feet, face masks or shields provided markedly decreased aerosol transmission in a room with limited ventilation. At two feet, with a type of protection wearing manikin emitting aerosols of normal saline and a non-barrier receiver, the aerosol transmission increased with the use of a KN95 (+ 20%), a washable cloth mask (+ 25%), a disposable shield (+ 7%), a 3D printed shield (+ 3%), and a shop shield (+ 15%) compared to the case with no PPE used on either. Changing the angle at which the two manikins are facing each other affected aerosol transmission; compared to the manikins wearing an N95 mask and facing each other, an angle of 45° and 90° increased transmission by 43% and 52%, respectively. With both the generator and receiver wearing a disposable medical mask, aerosols detected at all distances were significantly attenuated. In the system tested, masks generally provided superior aerosol transmission reduction when compared to face shields. These resultsare not intended to guide PPE selection but may serve as a framework for future research and advanced testing methodology. It is reassuring to confirm however that the distance between the aerosol transmitter and receiver significantly reduced aerosol exposure and that a simple surgical mask worn by both transmitter and receiver markedly reduced transmission to near background levels. The manikin represents a scaled-down model; therefore, absolute flow fields differ from adult physiology. The findings should be interpreted in relative rather than absolute terms.

Scientific ReportsVol. 16(1)
University of British Columbia (CA), The University of Queensland (AU), BC Children's Hospital (CA)
Openalex Percentile: Top 84%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.