Study of beam position monitors for PERLE
PERLE is an Energy-Recovery Linac (ERL) to be constructed at IJCLab in Orsay. It will be the First multi-turn ERL with superconducting RF (SRF) with the ambition to reach 10MW beam operation (20mA beam current and 500MeV beam energy) Diagnostics are a key element for PERLE operation and among diagnostics, the salient feature for Beam position monitors (BPMs) is the presence of multiple beams which need to be individually diagnosed and controlled. This document describes the design and the operation of PERLE BPMs with particular attention given to how these BPMs will handle multiple beams during commissioning and under normal operation of PERLE
Authors
- Sidi Mohammed Ben Abdillah
Publication Details
- Journal
- SPIRE - Sciences Po Institutional REpository
- Published
- 2026-01-20
- DOI
- https://doi.org/10.18429/jacow-ibic2025-wepco37
- Primary Topic
- Particle accelerators and beam dynamics
- Type
- article
- Field-Weighted Citation Impact
- 0.00