In Vivo Determination of Skin Absorption Coefficient in a Mexican Cohort

We determined the in vivo absorption coefficient (μa) for 82 test subjects, all classified as Fitzpatrick skin phototypes II, III, IV, and V. Measurements were conducted using the integrating-sphere technique on the dorsal and palmar surfaces of the hand and the forearm. The reflectance data obtained were processed using the Inverse Adding Doubling algorithm to calculate the absorption coefficient. The mean values for this parameter ranged from 0.0132 mm−1 to 0.1021 mm−1 at a central wavelength of 624 nm. It was found that these parameters may be grouped into a distinct cohort, paving the way for studies and the design of light-based diagnostics and treatments better suited to the population in Mexico and Latin America.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-01-19
DOI
https://doi.org/10.3390/app16021021
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vivo Determination of Skin Absorption Coefficient in a Mexican Cohort

Juan A. Ramírez-Quintana, Didia Patricia Salas-Peimbert, Erick Enrique Amezcua-López, Luis Francisco Corral-Martínez et al.
Applied Sciences
Optical Imaging and Spectroscopy Techniques
article

In Vivo Determination of Skin Absorption Coefficient in a Mexican Cohort

Juan A. Ramírez-Quintana, Didia Patricia Salas-Peimbert, Erick Enrique Amezcua-López, Luis Francisco Corral-Martínez, Marcelino Anguiano-Morales
article en

Abstract

We determined the in vivo absorption coefficient (μa) for 82 test subjects, all classified as Fitzpatrick skin phototypes II, III, IV, and V. Measurements were conducted using the integrating-sphere technique on the dorsal and palmar surfaces of the hand and the forearm. The reflectance data obtained were processed using the Inverse Adding Doubling algorithm to calculate the absorption coefficient. The mean values for this parameter ranged from 0.0132 mm−1 to 0.1021 mm−1 at a central wavelength of 624 nm. It was found that these parameters may be grouped into a distinct cohort, paving the way for studies and the design of light-based diagnostics and treatments better suited to the population in Mexico and Latin America.

Applied SciencesVol. 16(2)
Tecnológico Nacional de México (MX)
Openalex Percentile: Top 84%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.