The Hefei Light Source is a synchrotron radiation facility operating in the vacuum ultraviolet and soft X-ray regions. If the evolution of beam parameters and beam loss during the injection transient process can be observed synchronously, analyzing their correlation can provide more quantitative guidance for further optimizing the injection process. To achieve this goal, a monitoring system capable of synchronously capturing the 3D position of each bunch and rapid beam loss has been established at the Hefei Light Source. Experiments investigated both TOP-UP injection and empty-ring injection processes. Thanks to the unique multi-parameter synchronous diagnosis capability of this system, some previously unnoticed special phenomena have been captured, and a deeper analysis of the correlation between bunch parameters can be conducted. TOP-UP mode exhibited maximum beam loss in the injected bunch, with secondary losses at the 14th subsequent bunch. Peak beam loss occurred immediately after injection in both modes, followed by rapid attenuation within several turns. Loss resurgence appeared after ~85 turns (TOP-UP) or 180 turns (empty ring), followed by oscillatory decay.

Authors

Publication Details

Journal
JACOW
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-mopmo16
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Joint analysis of beam loss and beam position during the injection process at Hefei light source

Yunzhi Xiao, Yihong Liu, Yongbin Leng
JACOW
Particle Accelerators and Free-Electron Lasers
article

Joint analysis of beam loss and beam position during the injection process at Hefei light source

Yunzhi Xiao, Yihong Liu, Yongbin Leng
article en

Abstract

The Hefei Light Source is a synchrotron radiation facility operating in the vacuum ultraviolet and soft X-ray regions. If the evolution of beam parameters and beam loss during the injection transient process can be observed synchronously, analyzing their correlation can provide more quantitative guidance for further optimizing the injection process. To achieve this goal, a monitoring system capable of synchronously capturing the 3D position of each bunch and rapid beam loss has been established at the Hefei Light Source. Experiments investigated both TOP-UP injection and empty-ring injection processes. Thanks to the unique multi-parameter synchronous diagnosis capability of this system, some previously unnoticed special phenomena have been captured, and a deeper analysis of the correlation between bunch parameters can be conducted. TOP-UP mode exhibited maximum beam loss in the injected bunch, with secondary losses at the 14th subsequent bunch. Peak beam loss occurred immediately after injection in both modes, followed by rapid attenuation within several turns. Loss resurgence appeared after ~85 turns (TOP-UP) or 180 turns (empty ring), followed by oscillatory decay.

JACOW
Openalex Percentile: Top 82%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.