Multi-resolution tone mapping for high dynamic range medical ultrasound images

Ultrasound diagnostics is a key tool in obstetrics for detecting fetal anomalies and monitoring pregnancy, but image quality often declines in obese patients due to reduced contrast resolution. This pilot study develops and preliminarily validates a novel tone-mapping algorithm for enhancing contrast resolution in high dynamic range (HDR) ultrasound images. The method employs multi-resolution fusion with depth-adaptive weighting and depth compensation to improve contrast, enhance tissue differentiation, reduce noise, and preserve fine details. The algorithm was tested on 20 fetal ultrasound images focused on fetal kidney visualization. Quantitative evaluation showed a 5.4% mean increase in entropy and mean generalized contrast-to-noise ratio (gCNR) improvements of 15.79%, 8.93%, and 17.39% between fetal kidneys and amniotic fluid, far-field objects and fluid, and fetal kidneys and adjacent tissues, respectively, compared with an existing method. These results demonstrate improved anatomical visualization, particularly of fetal kidneys, with potential clinical relevance.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-01-20
DOI
https://doi.org/10.1371/journal.pone.0340777
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-resolution tone mapping for high dynamic range medical ultrasound images

Christina Verena Haberl, Otmar Scherzer, Vimal Chandran, Julia Binder et al.
PLoS ONE
Ultrasound Imaging and Elastography
article

Multi-resolution tone mapping for high dynamic range medical ultrasound images

Christina Verena Haberl, Otmar Scherzer, Vimal Chandran, Julia Binder, Thi Lan Nhi Vu
article en

Abstract

Ultrasound diagnostics is a key tool in obstetrics for detecting fetal anomalies and monitoring pregnancy, but image quality often declines in obese patients due to reduced contrast resolution. This pilot study develops and preliminarily validates a novel tone-mapping algorithm for enhancing contrast resolution in high dynamic range (HDR) ultrasound images. The method employs multi-resolution fusion with depth-adaptive weighting and depth compensation to improve contrast, enhance tissue differentiation, reduce noise, and preserve fine details. The algorithm was tested on 20 fetal ultrasound images focused on fetal kidney visualization. Quantitative evaluation showed a 5.4% mean increase in entropy and mean generalized contrast-to-noise ratio (gCNR) improvements of 15.79%, 8.93%, and 17.39% between fetal kidneys and amniotic fluid, far-field objects and fluid, and fetal kidneys and adjacent tissues, respectively, compared with an existing method. These results demonstrate improved anatomical visualization, particularly of fetal kidneys, with potential clinical relevance.

PLoS ONEVol. 21(1)
University of Vienna (AT), Christian Doppler Laboratory for Thermoelectricity (AT), Johann Radon Institute for Computational and Applied Mathematics (AT), Medical University of Vienna (AT)
Österreichische Nationalstiftung für Forschung, Technologie und Entwicklung, Universität Wien, Christian Doppler Forschungsgesellschaft, Bundesministerium für Digitalisierung und Wirtschaftsstandort
Good health and well-being
Openalex Percentile: Top 84%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.