Online position conversion factor calibration study for BPM system

Transverse beam position is one of the most critical parameters in accelerator commission and operation. As non-invasive diagnostic devices, beam position monitors (BPMs) are the main “workhorse” in accelerators, providing beam center of mass position information. The position conversion factor (K-factor) of BPM systems constitutes a fundamental determinate of measurement accuracy. While precision calibration traditionally relies on moveable calibrate platforms, the prohibitive cost of equipping each BPM with a dedicated two-dimensional calibration platform remains a widespread practical constraint. In this paper, an innovative online calibration method that synergizes machine learning with beam response matrix analysis to achieve per-BPM K-factor determination is introduced. The preliminary beam experiments have been carried out at Shanghai Soft X-ray Free-Electron Laser (SXFEL) facility. The proposed method offers a robust and resource-efficient calibration solution, particularly advantageous for cavity BPM systems where conventional approaches such as theoretical calculation and offline wire scanning, fail to provide reliable results.

Authors

Publication Details

Journal
JACOW
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-wepmo09
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Online position conversion factor calibration study for BPM system

H.J. Chen, Renxian Yuan, Jian Chen
JACOW
Particle Accelerators and Free-Electron Lasers
article

Online position conversion factor calibration study for BPM system

H.J. Chen, Renxian Yuan, Jian Chen
article en

Abstract

Transverse beam position is one of the most critical parameters in accelerator commission and operation. As non-invasive diagnostic devices, beam position monitors (BPMs) are the main “workhorse” in accelerators, providing beam center of mass position information. The position conversion factor (K-factor) of BPM systems constitutes a fundamental determinate of measurement accuracy. While precision calibration traditionally relies on moveable calibrate platforms, the prohibitive cost of equipping each BPM with a dedicated two-dimensional calibration platform remains a widespread practical constraint. In this paper, an innovative online calibration method that synergizes machine learning with beam response matrix analysis to achieve per-BPM K-factor determination is introduced. The preliminary beam experiments have been carried out at Shanghai Soft X-ray Free-Electron Laser (SXFEL) facility. The proposed method offers a robust and resource-efficient calibration solution, particularly advantageous for cavity BPM systems where conventional approaches such as theoretical calculation and offline wire scanning, fail to provide reliable results.

JACOW
Decent work and economic growth
Openalex Percentile: Top 82%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.