Factors Affecting Plastic Fluidity of Foam Conditioned Soil under Pressurized Conditions

Plasticity behavior of the foam-conditioned soil in the chamber is critical in the earth pressure balanced shield tunneling operation. An experimental study was conducted to evaluate the factors affecting the plastic fluidity of the air-foamed sand under pressures close to the actual field, and to clarify the relationship with that under atmospheric pressure. Plastic fluidity of the air-foamed sand was highly dependent on the difference between the overburden pressure and foam injection pressure, which is normalized by the overburden pressure. Another critical factor was the foam expansion ratio (FER). Foam-conditioned sand with FER = 16 maintained higher plasticity than that with FER = 8, when subjected to an equivalent increment of effective stress. However, the higher FER led to the larger residual volume change after a loading-unloading cycle. The table flow test is widely employed as an index of the plastic fluidity of foam-conditioned soil. The table flow values measured under atmospheric pressure do not completely correspond to the plastic fluidity under high-pressure conditions.

Authors

Institutions

Publication Details

Journal
Journal of the Society of Materials Science Japan
Published
2026-01-15
DOI
https://doi.org/10.2472/jsms.75.70
Primary Topic
Tunneling and Rock Mechanics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factors Affecting Plastic Fluidity of Foam Conditioned Soil under Pressurized Conditions

Toru Inui, Toshihiko Miura, Yukinobu Kimura, Kanta MIYAZAWA et al.
Journal of the Society of Materials Science Japan
Tunneling and Rock Mechanics
article

Factors Affecting Plastic Fluidity of Foam Conditioned Soil under Pressurized Conditions

Toru Inui, Toshihiko Miura, Yukinobu Kimura, Kanta MIYAZAWA, Sho OGATA, Atsushi TAKEDA
article en

Abstract

Plasticity behavior of the foam-conditioned soil in the chamber is critical in the earth pressure balanced shield tunneling operation. An experimental study was conducted to evaluate the factors affecting the plastic fluidity of the air-foamed sand under pressures close to the actual field, and to clarify the relationship with that under atmospheric pressure. Plastic fluidity of the air-foamed sand was highly dependent on the difference between the overburden pressure and foam injection pressure, which is normalized by the overburden pressure. Another critical factor was the foam expansion ratio (FER). Foam-conditioned sand with FER = 16 maintained higher plasticity than that with FER = 8, when subjected to an equivalent increment of effective stress. However, the higher FER led to the larger residual volume change after a loading-unloading cycle. The table flow test is widely employed as an index of the plastic fluidity of foam-conditioned soil. The table flow values measured under atmospheric pressure do not completely correspond to the plastic fluidity under high-pressure conditions.

Journal of the Society of Materials Science JapanVol. 75(1)
Obayashi (Japan) (JP), Osaka University of Economics (JP), The University of Osaka (JP)
Life in Land
Openalex Percentile: Top 83%
Tunneling and Rock Mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.