A copper oxide-modified laser-induced graphene electrode for the non-enzymatic and simultaneous detection of glucose and creatinine

Dual Cu(I)/Cu(II)/Cu(III) redox states in Cu 2 O/CuO-modified laser-induced graphene enable simultaneous, non-enzymatic detection of glucose and creatinine with high selectivity and stability. • Simple, scalable flash oxidation yields stable Cu 2 O/CuO nanoparticles on LIG. • Copper oxide-modified laser-induced graphene enables dual-analyte detection. • Distinct redox states of copper drive selective glucose and creatinine sensing. • Simultaneous, non-enzymatic detection without cross-interference. • Sensor shows low detection limits, high reproducibility, and long-term stability. Non-enzymatic biosensors are promising alternatives to enzyme-based sensors for personalized health monitoring because they offer lower cost, improved stability, and simpler fabrication. Nevertheless, their practical use remains limited by insufficient sensitivity, selectivity, and long-term stability, highlighting the need for robust and highly functional nanomaterial-based sensing platforms. In this study, we developed a laser-induced graphene (LIG) electrode modified with copper oxide (Cu x O, comprising coexisting Cu 2 O and CuO phases) for use in non-enzymatic biosensing applications. Systematic surface analysis confirmed the successful formation of Cu x O on the LIG structure. The incorporation of Cu x O nanoparticles significantly increased the surface area of the electrode, providing abundant active sites and enhancing its electrochemical properties. Owing to the unique redox mechanism of Cu x O, the sensor was able to selectively and sensitively detect both glucose and creatinine. The Cu x O-LIG sensor exhibited sensitive detection for glucose and creatinine within the ranges of 0–5.5 mM and 0–0.5 mM, with limits of detection of 84 μM and 5.4 μM, respectively. Moreover, well-separated oxidation potentials for glucose (0.65 V) and creatinine (0.04 V), enabled simultaneous detection. These results demonstrate the potential of the Cu x O–LIG platform as a robust non-enzymatic biosensor for multi-biomarker monitoring in healthcare applications.

Authors

Institutions

Publication Details

Journal
Applied Surface Science
Published
2026-01-20
DOI
https://doi.org/10.1016/j.apsusc.2026.166003
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
21.93
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A copper oxide-modified laser-induced graphene electrode for the non-enzymatic and simultaneous detection of glucose and creatinine

Yun-Hoe Koo, G Lee, A‐Rang Jang, Sunwoo Lee et al.
1 citations
Applied Surface Science
Electrochemical sensors and biosensors
21.93
article

A copper oxide-modified laser-induced graphene electrode for the non-enzymatic and simultaneous detection of glucose and creatinine

Yun-Hoe Koo, G Lee, A‐Rang Jang, Sunwoo Lee, Jong‐Heon Kim, Du Won Jeong, Gye Hyeon Lee, Jeong-O Lee, Donghwi Cho, Seong Eun Son, Minsoo Lee, Ji Yeon Shin
article en
1 citations

Abstract

Dual Cu(I)/Cu(II)/Cu(III) redox states in Cu 2 O/CuO-modified laser-induced graphene enable simultaneous, non-enzymatic detection of glucose and creatinine with high selectivity and stability. • Simple, scalable flash oxidation yields stable Cu 2 O/CuO nanoparticles on LIG. • Copper oxide-modified laser-induced graphene enables dual-analyte detection. • Distinct redox states of copper drive selective glucose and creatinine sensing. • Simultaneous, non-enzymatic detection without cross-interference. • Sensor shows low detection limits, high reproducibility, and long-term stability. Non-enzymatic biosensors are promising alternatives to enzyme-based sensors for personalized health monitoring because they offer lower cost, improved stability, and simpler fabrication. Nevertheless, their practical use remains limited by insufficient sensitivity, selectivity, and long-term stability, highlighting the need for robust and highly functional nanomaterial-based sensing platforms. In this study, we developed a laser-induced graphene (LIG) electrode modified with copper oxide (Cu x O, comprising coexisting Cu 2 O and CuO phases) for use in non-enzymatic biosensing applications. Systematic surface analysis confirmed the successful formation of Cu x O on the LIG structure. The incorporation of Cu x O nanoparticles significantly increased the surface area of the electrode, providing abundant active sites and enhancing its electrochemical properties. Owing to the unique redox mechanism of Cu x O, the sensor was able to selectively and sensitively detect both glucose and creatinine. The Cu x O-LIG sensor exhibited sensitive detection for glucose and creatinine within the ranges of 0–5.5 mM and 0–0.5 mM, with limits of detection of 84 μM and 5.4 μM, respectively. Moreover, well-separated oxidation potentials for glucose (0.65 V) and creatinine (0.04 V), enabled simultaneous detection. These results demonstrate the potential of the Cu x O–LIG platform as a robust non-enzymatic biosensor for multi-biomarker monitoring in healthcare applications.

Applied Surface ScienceVol. 727
Institute of Chemical Technology (IN), Kongju National University (KR), Korea Research Institute of Chemical Technology (KR)
Openalex Percentile: Top 2%
Electrochemical sensors and biosensors
21.93
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.