Bunch-by-bunch beam current and lifetime measurement with interleaved sampling at HLS

To achieve high-precision, bunch-by-bunch beam cur-rent and lifetime measurements at the Hefei Light Source (HLS), we developed a beam diagnostics system based on interleaved sampling technology, achieving an equivalent sampling rate of 6.5 GHz. In single-bunch mode, amplitude extraction via cross-correlation with a single response function yieds a turn-by-turn current relative resolution of 0.12%. By averaging over 200 turns, the resolution is improved to 0.04% at a 23 kHz data refresh rate, enabling fast and accurate lifetime calculations. However, in multi-bunch high-current mode, large longitudinal oscillations degrade the accura-cy of amplitude extraction when using a fixed-response function. We propose an integration method to mitigate the effects of bunch length and phase oscillations on beam current measurements. The method and experi-mental results provide a practical solution for machines exhibiting large longitudinal oscillations, such as HLS.

Authors

Publication Details

Journal
JACOW
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-mopmo01
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bunch-by-bunch beam current and lifetime measurement with interleaved sampling at HLS

Youming Deng, Jianhui Chen, An Wang, Xing Yang et al.
JACOW
Particle Accelerators and Free-Electron Lasers
article

Bunch-by-bunch beam current and lifetime measurement with interleaved sampling at HLS

Youming Deng, Jianhui Chen, An Wang, Xing Yang, Yongbin Leng
article en

Abstract

To achieve high-precision, bunch-by-bunch beam cur-rent and lifetime measurements at the Hefei Light Source (HLS), we developed a beam diagnostics system based on interleaved sampling technology, achieving an equivalent sampling rate of 6.5 GHz. In single-bunch mode, amplitude extraction via cross-correlation with a single response function yieds a turn-by-turn current relative resolution of 0.12%. By averaging over 200 turns, the resolution is improved to 0.04% at a 23 kHz data refresh rate, enabling fast and accurate lifetime calculations. However, in multi-bunch high-current mode, large longitudinal oscillations degrade the accura-cy of amplitude extraction when using a fixed-response function. We propose an integration method to mitigate the effects of bunch length and phase oscillations on beam current measurements. The method and experi-mental results provide a practical solution for machines exhibiting large longitudinal oscillations, such as HLS.

JACOW
Affordable and clean energy
Openalex Percentile: Top 82%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.