Digital signal processing improvements of the SPIRAL2 beam position monitors at low intensity

The SPIRAL2 accelerator, designed for high intensity beams (up to 5 mA), needs to evolve for low intensities in order to reach the requirements of the S3 experimental room. This means increasing the operating range of diagnostic monitors including the Beam Position Monitors (BPM). Twenty BPM are installed in the warm sections of the linac to measure positions, ellipticities and phases. The digital processing of the BPM acquisition has been modified to operate at low intensity. This was done by improving the signal-to-noise ratio with an increase of the averaging resolution, an improvement of the channel equalisation system and with a deduction of parasitic signals induced by the surrounding equipment. The process was also modified to operate with chopper frequencies between 1 Hz and 1 kHz. A new BPM interface, with tables and graphical displays in order to control beam phases and energies in the linac, is now available. These new developments and measurement results in laboratory and with SPIRAL2 beams are presented, which show good results with a low intensity down to 1 µA.

Authors

Publication Details

Journal
SPIRE - Sciences Po Institutional REpository
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-wepmo12
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital signal processing improvements of the SPIRAL2 beam position monitors at low intensity

Olivier Delahaye, C. Potier de Courcy, Charles Houarner, Pierre Salou et al.
SPIRE - Sciences Po Institutional REpository
Particle Accelerators and Free-Electron Lasers
article

Digital signal processing improvements of the SPIRAL2 beam position monitors at low intensity

Olivier Delahaye, C. Potier de Courcy, Charles Houarner, Pierre Salou, Clément Tréangle, Simon Rueff, Christophe Jamet
article en

Abstract

The SPIRAL2 accelerator, designed for high intensity beams (up to 5 mA), needs to evolve for low intensities in order to reach the requirements of the S3 experimental room. This means increasing the operating range of diagnostic monitors including the Beam Position Monitors (BPM). Twenty BPM are installed in the warm sections of the linac to measure positions, ellipticities and phases. The digital processing of the BPM acquisition has been modified to operate at low intensity. This was done by improving the signal-to-noise ratio with an increase of the averaging resolution, an improvement of the channel equalisation system and with a deduction of parasitic signals induced by the surrounding equipment. The process was also modified to operate with chopper frequencies between 1 Hz and 1 kHz. A new BPM interface, with tables and graphical displays in order to control beam phases and energies in the linac, is now available. These new developments and measurement results in laboratory and with SPIRAL2 beams are presented, which show good results with a low intensity down to 1 µA.

SPIRE - Sciences Po Institutional REpository
Affordable and clean energy
Openalex Percentile: Top 83%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.